Alpha Essentials Data & Bus cables offer industry-leading mechanical and electrical performance for the major industrial automation protocols, including ControlNet™, RS-485, DeviceNet™, Fieldbus, PROFIBUS™, and Industrial Twinax. With multiple configurations, we are sure to meet the needs of your demanding applications.
ControlNet™ Cable
- Low-loss RG-6/U 75-ohm coaxial cable
- Double braid/foil shielding for maximum signal integrity and run length
RS-485 Cable
- 1 to 4 pairs
- Braid/foil shield to reduce electrical noise sensitivity
- UL Type PLTC Open Wiring (300 V)
- Sunlight resistant
DeviceNet™ Cable
- Power and data in a rugged two-pair cable
- Sunlight resistant
- Available for ODVA thick and thin trunks
- Compliant with Allen-Bradley part numbers 1485 CPI-A and 1485 CPI-C
Fieldbus and PROFIBUS™ Cable
- 100-ohm impedance for Types A and B Fieldbus
- 150-ohm impedance for High-Speed Fieldbus and PROFIBUS DP
Industrial Twinax Cable
- Meets the requirements of Allen-Bradley Data Highway Networks
Diameter ("in") | ||||||||||||||
1) Component 1 | 2 x 1 COND | |||||||||||||
a) Conductor | 18 (7/26) AWG Tinned Copper | 0.046 | ||||||||||||
b) Insulation | 0.025" Wall, Nom. FRPP | 0.096 | ||||||||||||
(1) Color(s) | ||||||||||||||
|
||||||||||||||
2) Cable Assembly | 2 Components Cabled | |||||||||||||
a) Twists | 6.9 Twists/ft. (min.) | |||||||||||||
b) Orientation | Components to be arranged from INSIDE LAYER-to-OUTSIDE LAYER | |||||||||||||
3) Shield | Alum/Mylar Tape, 25% Overlap (min.) | |||||||||||||
a) Foil Direction | Foil Facing Out | |||||||||||||
b) Drain Wire | 20 (7/28) AWG Tinned Copper | |||||||||||||
c) Braid | Tinned Copper, 55% Coverage (min.) | |||||||||||||
4) Jacket | 0.053" Wall, Nom., PVC | 0.324+/- 0.015 | ||||||||||||
a) Color(s) | BLUE | |||||||||||||
b) Print | ALPHA WIRE-* P/N 6450 EXXXXX 1PR18 SHIELDED (UL) 600V 75C DRY SUN RES TYPE TC OR PLTC OR ITC OR CMG OR C(UL) CMG --- P-MSHA (MSHA #) CE ROHS (SEQ FOOTAGE EVERY 2 FT) * = Factory Code Note: Product may have c(UL) or CSA markings depending upon plant of manufacture. |
1) UL | TC | 75°C / 600 VRMS |
PLTC | 75°C | |
ITC | 75°C | |
CMG | 75°C | |
SUN RES | ||
2) CSA International | CMG | 75°C |
FT4 | ||
3) Other | PMSHA Specification | |
4) CE | EU Low Voltage Directive 2014/35/EU |
1) CE: EU Directive 2011/65/EU(RoHS2) | ||
This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011and the amending Directive 2015/863/EU of 4 June 2015 . No exemptions are required for RoHS Compliance on this item. Refer to the RoHS Certificate of Compliance for more detail. |
Physical & Mechanical Properties | |
---|---|
1) Temperature Range | -40 to 75°C |
2) Bend Radius | 10X Cable Diameter |
3) Pull Tension | 40 lbs. max. |
Electrical Properties | Engineering purposes only |
1) Voltage Rating | 600 VRMS |
2) Characteristic Impedance | 78 Ω +/- 5 |
3) Inductance | 0.12 µH/ft., Nominal |
4) Mutual Capacitance | 19.5 pF/ft. @1 kHz, Nominal |
5) Velocity of Propagation | 65% |
6) Conductor DCR | 6.9 Ω/1000ft. @20°C, Nominal |
7) OA Shield DCR | 3.2 Ω/1000ft. @20°C, Nominal |
8) Attenuation (max. dB/100ft.) | 0.5 @ MHz |
2 @10 MHz | |
3.8 @50 MHz | |
5.4 @100 MHz | |
7.6 @200 MHz | |
10.7 @400 MHz |
Packaging | Flange x Traverse x Barrel (inches) |
a) 1000 FT | 18 x 12 x 8 Continuous Length |
b) 500 FT | 12 x 12 x 3.5 Continuous Length |
c) 100 FT | 12 x 4.5 x 3.5 Continuous Length |
Spool dimensions may vary slightly. |