Cords and Cordsets 101
Cords and Cordsets 101

This picture is representative only and may not match the specific configuration of the product listed on this page. Please refer to the product specifications for more information on this part number and its exact configuration.
For consumer and industrial devices, business and communication machines, and medical and test equipment, our cords give you everything you need for reliable plugin power. All our cords are UL Listed and CSA Certified; we also offer a wide range of CENELEC-approved products for international use. Options include two- and three-conductor cords, shielded or unshielded, stripped and terminated cable ends, straight or retractile cords, and all common plug and receptacle configurations.
Construction
Diameters (In) | ||||||||||||||||||||
1) Component 1 | 4 X 1 COND | |||||||||||||||||||
a) Conductor | 22 (26/36) AWG Bare Copper | 0.027 | ||||||||||||||||||
b) Insulation | 0.010" Wall, Nom. MPPE | 0.047 | ||||||||||||||||||
(1) Color(s) | ||||||||||||||||||||
| ||||||||||||||||||||
2) Cable Assembly | 4 Components Cabled | |||||||||||||||||||
a) Twists: | 6.9 Twists/foot (min) | |||||||||||||||||||
b) Orientation: | Components to be arranged from INSIDE LAYER to OUTSIDE LAYER | |||||||||||||||||||
3) Jacket | 0.040" Wall, Nom.,Polyurethane, Zero Halogen (ZH) | 0.200+/- 0.011 | ||||||||||||||||||
a) Color(s) | SLATE | |||||||||||||||||||
b) Jacket Separator | Tissue Tape, 25% Overlap, Min. | |||||||||||||||||||
c) Print | ALPHA WIRE-* P/N 101 4C 22 AWG E163869 RU AWM STYLE 21959 90C 600V SUN RES 60C OIL OR STYLE 20549 80C 300V OR CRU AWM I/II A/B 90C 600V FT2 --- IEC EN 60332-1/2 CE ROHS SUITABLE FOR USE WITHIN EQUIPMENT ONLY * = Factory Code |
Applicable Specifications
1) UL | ||
a) Component 1 | AWM/STYLE 11231 | 105°C / 600 VRMS |
b) Overall | AWM/STYLE 21959 | 90°C / 600 VRMS |
60C OIL | ||
SUN RES | ||
AWM/STYLE 20549 | 80°C / 300 VRMS | |
2) CSA International | C(RU) AWM I/II A/B | 90°C / 600 VRMS |
FT2 | ||
3) IEC | ||
a) Component 1 | EN 60228 Conductors, Class 6 | |
b) Overall | EN 60754-1 Acid Gas Generation | |
EN 60754-2 Acid Gas Generation | ||
EN 60332-1 Flame Behavior | ||
EN 60332-2 Flame Behavior | ||
4) CE: | EU Low Voltage Directive 2014/35/EC |
Environmental
1) CE: EU Directive 2011/65/EU(RoHS2): | ||
This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011 and the amending Directive 2015/863/EU of 4 June 2015 . No Exemptions are required for RoHS Compliance on this item. Consult Alpha Wire's web site for RoHS C of C. | ||
2) REACH Regulation (EC 1907/2006): | ||
This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, please see Alpha's REACH SVHC Declaration. |
Properties
Physical & Mechanical Properties | |
---|---|
1) Temperature Range | -50 to 90°C(static), -40 to 80°C (dynamic) |
2) Bend Radius | 4X Cable Diameter(static), 6X Cable Diameter(dynamic) |
3) Pull Tension | 20.4 Lbs, Maximum |
4) Sunlight Resistance | Yes |
Electrical Properties | (For Engineering purposes only) |
1) Voltage Rating | 600 VRMS |
2) Capacitance | 16.2 pF/ft @1 kHz, Nominal Conductor to Conductor |
3) Inductance | 0.18 µH/ft, Nominal |
4) Conductor DCR | 16.4 Ω/1000ft @20°C, Nominal |
Other
Packaging | Flange x Traverse x Barrel (inches) |
a) Bulk(Made-to-order) |