Diameter ("in") | ||||||||||||||
1) Component 1 | 1 x 1 COAX | |||||||||||||
a) Conductor | 18 (SOLID) AWG BCW | 0.040 | ||||||||||||
b) Insulation | 0.065" Wall, Nom. Foam FEP Teflon | 0.170 | ||||||||||||
(1) Color(s) | ||||||||||||||
|
||||||||||||||
2) Shield: | Alum/Mylar Tape, 25% Overlap (min.) | |||||||||||||
a) Foil Direction | Foil Facing Out | |||||||||||||
b) Braid | TC,95% Coverage (min.) | |||||||||||||
3) Jacket | 0.014" Wall, Nom. PVDF | 0.232 (0.238 max.) | ||||||||||||
a) Color(s) | BLACK | |||||||||||||
b) Print | ALPHA WIRE-* P/N 9104 RG 6/U TYPE SHIELDED 1C 18 AWG 125C (UL) TYPE CMP OR CATVP C(UL) CMP FT6 CE ROHS * = Factory Code Note: Product may have c(UL) or CSA markings depending upon plant of manufacture. |
1) UL | CMP | 125°C |
CATVP | 125°C | |
2) CSA International | C(UL) TYPE CMP | 125°C |
FT6 | ||
3) Military | MIL-C-17/RG-6/U Type | |
4) CE | EU Low Voltage Directive 2006/95/EC |
1) CE: EU Directive 2011/65/EU(RoHS2) | ||
This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011. No exemptions are required for RoHS Compliance on this item. Consult Alpha Wire's web site for RoHS Certificate of Compliance. | ||
2) REACH Regulation (EC 1907/2006) | ||
This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, see Alpha's REACH SVHC Declaration. | ||
3) California Proposition 65 | Outer surface materials used in manufacturing this part meet the requirements of California Proposition 65. |
Physical & Mechanical Properties | |
---|---|
1) Temperature Range | -40 to 125°C |
2) Bend Radius | 10X Cable Diameter |
3) Pull Tension | 22.2 lbs. max. |
Electrical Properties | Engineering purposes only |
1) Voltage Rating | 300 VRMS |
2) Characteristic Impedance | 75 Ω +/- 3 |
3) Inductance | 0.1 µH/ft, Nominal |
4) Mutual Capacitance | 16.5 pf/ft @1 kHz, Nominal |
5) Velocity of Propagation | 82% |
6) Conductor DCR | 16.3 Ω/1000ft @20°C, Nominal |
7) OA Shield DCR | 1.76 Ω/1000ft @20°C, Nominal |
8) Attenuation, Nom dB/100ft | 0.3 @ 1 MHz |
0.66 @ 10 MHz | |
1.6 @ 50 MHz | |
2.2 @ 100 MHz | |
3 @ 200 MHz | |
4.6 @ 400 MHz |
Packaging | Flange x Traverse x Barrel (inches) |
a) 1000 FT | 12 x 10 x 5 Continuous Length |
b) 500 FT | 12 x 4.5 x 3.5 Continuous Length |
Spool dimensions may vary slightly. |