Diameter ("in") | ||||||||||||||
1) Component 1 | 1 x 1 COAX | |||||||||||||
a) Conductor | 23 (SOLID) AWG BC | 0.023 | ||||||||||||
b) Insulation | 0.0615" Wall, Nom. Polyethylene (PE) | 0.146 | ||||||||||||
(1) Color(s) | ||||||||||||||
|
||||||||||||||
2) Shield: | A/P/A Tape, 25% Overlap, min. | |||||||||||||
a) Braid | TC,95% Coverage, Min. | |||||||||||||
3) Jacket | 0.023" Wall, Nom., Type IIIA, PE | 0.220+/- 0.004 | ||||||||||||
a) Color(s) | BLACK | |||||||||||||
b) Print | ALPHA WIRE-* P/N 9810 ROHS * = Factory Code |
1) Military | MIL-C-17/RG 59/U type |
1) EU Directive 2011/65/EU(RoHS2) | ||
All materials used in the manufacture of this part are in compliance with European Directive 2011/65/EU regarding the restriction of use of certain hazardous substances in electrical and electronic equipment. Refer to the RoHS Certificate of Compliance for more detail. | ||
2) REACH Regulation (EC 1907/2006) | ||
This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, please see Alpha's REACH SVHC Declaration. | ||
3) California Proposition 65 | Outer surface materials used in manufacturing this part meet the requirements of California Proposition 65. |
Physical & Mechanical Properties | |
---|---|
1) Temperature Range | -55 to 80°C |
2) Bend Radius | 10X Cable Diameter |
3) Pull Tension | 9.3 lbs. max. |
Electrical Properties | Engineering purposes only |
1) Voltage Rating | 1700 VRMS |
2) Characteristic Impedance | 75 Ω +/- 2 |
3) Ground Capacitance | 21 pf/ft @1 kHz, Nominal |
4) Velocity of Propagation | 66 % |
5) Conductor DCR | 20.4 Ω/1000ft @20°C, Nominal |
6) OA Shield DCR | 4 Ω/1000ft @20°C, Nominal |
7) Voltage Withstanding | 4 kV, min. |
8) Corona Extinction | 1.9 kV, min. |
9) SRL | 5 - 216 MHz, 27 db, min. |
217 - 850 MHz, 23 db, min. | |
10) Attenuation (Nom dB/100ft.) | 0.4 @ 1 MHz |
0.84 @ 5 MHz | |
1.17 @ 10 MHz | |
3.35 @ 100 MHz | |
8.3 @ 540 MHz | |
11.6 @ 1 GHz |
Packaging | Flange x Traverse x Barrel (inches) |
a) 1000 FT | 12 x 10 x 5 Continuous Length |
b) 100 FT | 6.5 x 4 x 2.5 Continuous Length |
Spool dimensions may vary slightly. |