Diameter ("in") | ||||||||||||||
1) Component 1 | 1 x 1 COAX | |||||||||||||
a) Conductor | 13 (7/21) AWG BC | 0.086 | ||||||||||||
b) Insulation | 0.0995" Wall, Nom. Polyethylene (PE) | 0.285 | ||||||||||||
(1) Color(s) | ||||||||||||||
|
||||||||||||||
2) Shield | BC BRAID Shield,94% Coverage (min.). | |||||||||||||
3) Jacket | 0.046" Wall, Nom. Type I PVC | 0.405+/- 0.007 | ||||||||||||
a) Color(s) | Black | |||||||||||||
b) Print | ALPHA WIRE-* P/N 9008 RG 8/U ROHS * = Factory Code |
1) Military | JAN-C-17A / RG-8/U | 60°C / 3700 VRMS |
1) EU Directive 2011/65/EU(RoHS2) | ||
All materials used manufacturing this part are in compliance with European Directive 2011/65/EU regarding the restriction of use of certain hazardous substances in electrical and electronic equipment. Refer to the RoHS Certificate of Compliance. | ||
2) REACH Regulation (EC 1907/2006) | ||
This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, refer to the Alpha Wire REACH SVHC Declaration. | ||
3) California Proposition 65 | Outer surface materials used in manufacturing this part meet the requirements of California Proposition 65. |
Physical & Mechanical Properties | |
---|---|
1) Temperature Range | -20 to 60°C |
2) Bend Radius | 10X Cable Diameter |
3) Pull Tension | 59 lbs. (max.) |
Electrical Properties | For Engineering purposes only |
1) Voltage Rating | 3700 VRMS |
2) Characteristic Impedance | 52 Ω +/- 2 |
3) Ground Capacitance | 29.5 pf/ft @1 kHz, Nominal |
4) Velocity of Propagation | 66 % |
5) Conductor DCR | 1.9 Ω/1000ft @20°C, Nominal |
6) OA Shield DCR | 1.29 Ω/1000ft @20°C, Nominal |
7) Voltage Withstanding | 10 kV (min.) |
8) Corona Extinction | 5 kV (min.) |
9) Attenuation (max. dB/100ft) | 2.3 @ 100 MHz |
6 @ 400 MHz | |
20 @ 3 GHz |
Packaging | Flange x Traverse x Barrel (inches) |
a) 1000 FT | 20 x 11 x 8 Continuous Length |
b) 500 FT | 16 x 11 x 8 Continuous Length |
c) 100 FT | 12 x 10 x 5 Continuous Length |
Spool dimensions may vary slightly |