Coaxial CableM4251
Alpha Wire offers 50-, 75-, 93-, and 100-ohm coaxial, twinaxial, and triaxial cables in a wide range of insulation and jacket materials and rated for UL, CSA and military specifications.
We now also provide non-magnetic coaxial cable options 9849 and 9851, which provide better signal transmission with minimal distortion while handling higher frequencies.
Looking for a space-saving option? We also offer Micro Coaxial cable, ideal for customers looking for uninterrupted signal transmission in compact spaces.
Diameter ("in") | ||||||||||||||
1) Component 1 | 1 x 1 COAX | |||||||||||||
a) Conductor | 19 (1/.037) AWG SCW | 0.037 | ||||||||||||
b) Insulation | 0.0395" Wall, Nom. PTFE | 0.116 | ||||||||||||
(1) Color(s) | ||||||||||||||
|
||||||||||||||
Individually Applied: | ||||||||||||||
c) Shield | SPC BRAID Shield,95% Coverage (min.) | |||||||||||||
2) Shield | SPC BRAID Shield,93% Coverage (min.) | |||||||||||||
3) Jacket | 0.017" Wall, Nom., FEP | 0.195+/- 0.005 | ||||||||||||
a) Color(s) | NATURAL TAN |
1) Military | MIL-C-17/RG 142B/U | 200°C / 1400 VRMS |
1) EU Directive 2011/65/EU(RoHS2): | ||
All materials used in the manufacture of this part are in compliance with European Directive 2011/65/EU regarding the restriction of use of certain hazardous substances in electrical and electronic equipment. Consult Alpha Wire's web site for RoHS C of C. | ||
2) REACH Regulation (EC 1907/2006): | ||
This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, please see Alpha's REACH SVHC Declaration. | ||
3) California Proposition 65: | Outer surface materials used in manufacturing this part meet the requirements of California Proposition 65. |
Physical & Mechanical Properties | |
---|---|
1) Temperature Range | -55 to 200°C |
2) Bend Radius | 10X Cable Diameter |
3) Pull Tension | 20 lbs. max. |
Electrical Properties | Engineering purposes only |
1) Voltage Rating | 1400 VRMS |
2) Characteristic Impedance | 50 Ω +/- 2 |
3) Inductance | 0.067 µH/ft., Nominal |
4) Ground Capacitance | 29 pf/ft. @1 kHz, Nominal |
5) Velocity of Propagation | 70 % |
6) Conductor DCR | 19.3 Ω/1000ft. @20°C, Nominal |
7) OA Shield DCR | 2.3 Ω/1000ft. @20°C, Nominal |
8) Voltage Withstanding | 5 kV (min.) |
9) Corona Extinction | 1.9 kV (min.) |
10) Attenuation (max. dB/100ft.) | 11.7 @ 400 MHz |
Packaging | Flange x Traverse x Barrel (inches) |
a) 1000 FT | 12 x 6 x 3.5 max. 3 separate pieces; Min length/piece 100 FT |
b) 500 FT | 12 x 4.5 x 3.5 max. 2 separate pieces; Min length/piece 100 FT |
c) 100 FT | 6.5 x 4 x 2.5 Continuous Length |
d) Bulk (made-to-order) | (Max. 3 pieces per 1000 FT/min. length 100 FT) |
Spool dimensions may vary slightly. |