Coaxial Cable9058C
Alpha Wire offers 50-, 75-, 93-, and 100-ohm coaxial, twinaxial, and triaxial cables in a wide range of insulation and jacket materials and rated for UL, CSA and military specifications.
We now also provide non-magnetic coaxial cable options 9849 and 9851, which provide better signal transmission with minimal distortion while handling higher frequencies.
Looking for a space-saving option? We also offer Micro Coaxial cable, ideal for customers looking for uninterrupted signal transmission in compact spaces.
Diameter ("in") | ||||||||||||||
1) Component 1 | 1 x 1 COAX | |||||||||||||
a) Conductor | 21 (19/.0072) AWG TC | 0.036 | ||||||||||||
b) Insulation | 0.040" Wall, Nom. Polyethylene (PE) | 0.116 | ||||||||||||
(1) Color(s) | ||||||||||||||
|
||||||||||||||
2) Shield | TC BRAID Shield,95% Coverage, Min. | |||||||||||||
3) Jacket | 0.028" Wall, Nom., Type IIA PVC | 0.195+/- 0.004 | ||||||||||||
a) Color(s) | BLACK | |||||||||||||
b) Print | ALPHA WIRE-* P/N 9058C RG 58C/U ROHS * = Factory Code |
1) Military | MIL-C-17/28B RG 58C/U |
1) EU Directive 2011/65/EU(RoHS2) | ||
All materials used in the manufacture of this part are in compliance with European Directive 2011/65/EU regarding the restriction of use of certain hazardous substances in electrical and electronic equipment. Refer to the RoHS Certificate of Compliance. | ||
2) REACH Regulation (EC 1907/2006) | ||
This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, please see Alpha's REACH SVHC Declaration. | ||
3) California Proposition 65 | Outer surface materials used in manufacturing this part meet the requirements of California Proposition 65. |
Physical & Mechanical Properties | |
---|---|
1) Temperature Range | -20 to 60°C |
2) Bend Radius | 10X Cable Diameter |
3) Pull Tension | 12.3 lbs. (max.) |
Electrical Properties | Engineering purposes only |
1) Voltage Rating | 1400 VRMS |
2) Characteristic Impedance | 50 Ω +/- 2 |
3) Ground Capacitance | 30.8 pf/ft @1 kHz, Nominal |
4) Velocity of Propagation | 66 % |
5) Conductor DCR | 11.5 Ω/1000ft @20°C, Nominal |
6) OA Shield DCR | 4.5 Ω/1000ft @20°C, Nominal |
7) Voltage Withstanding | 5 kV (min.) |
8) Corona Extinction | 1.9 kV (min.) |
9) Attenuation (max. dB/100ft) | 4 @ 50 MHz |
5.8 @ 100 MHz | |
17 @ 400 MHz | |
28 @ 1 GHz |
Packaging | Flange x Traverse x Barrel (inches) |
a) 1000 FT | 12 x 6 x 3.5 Continuous Length |
b) BOX 1000FT | 11-3/4 EASY REEL: Continuous Length |
c) 500 FT | 12 x 4.5 x 3.5 Continuous Length |
d) 100 FT | 6.5 x 4 x 2.5 Continuous Length |
Spool dimensions may vary slightly. |