EcoFlex®️ PUR80053
Get the abrasion, UV, and oil resistance of a tough zero-halogen Polyurethane jacket in a flex cable that’s up to 40% smaller and 44% lighter than other 600V continuous flex cables.
- Zero Halogen, contains no heavy metals or phthalates
- PUR jacket, mPPE insulation
- 8M+ flex life cycles
- finely stranded tinned copper conductors, class 6
- Up to 40% smaller and 44% lighter than standard 600V PUR continuous flex cables
- UL Oil Res I
- UL Sunlight Resistant
- Operating temperature -50C to +90C (static) and -40C to +80C (dynamic)
- Bend Radius 4X (static) and 6X (dynamic)
With its rugged PUR jacket and finely stranded conductors, EcoFlex PUR cable provides 8+ million flex cycles in tough application conditions—while saving space and reducing weight. And with a wide range of conductor sizes, conductor counts, and shielded and unshielded versions, you can find the cable you need.
Diameters (In) | ||||||||||||||||||||
1) Component 1 | 4 X 1 COND | |||||||||||||||||||
a) Conductor | 14 (105/34) AWG Tinned Copper | 0.070 | ||||||||||||||||||
b) Insulation | 0.013" Wall, Nom. MPPE | 0.096 | ||||||||||||||||||
(1) Print | ALPHANUMERIC NUMBERS - 1-ONE ALTERNATING AND INVERTED | |||||||||||||||||||
(2) Color Code | Alpha Wire Color Code KX | |||||||||||||||||||
| ||||||||||||||||||||
2) Cable Assembly | 4 Components Cabled | |||||||||||||||||||
a) Twists: | 4.4 Twists/foot (min) | |||||||||||||||||||
b) Orientation: | Components to be arranged from INSIDE LAYER to OUTSIDE LAYER | |||||||||||||||||||
c) Core Wrap | Nonwoven Polyester Tape, 25% Overlap, Min. | |||||||||||||||||||
3) Jacket | 0.032" Wall, Nom.,Polyurethane, Zero Halogen (ZH) | 0.301+/- 0.012 | ||||||||||||||||||
a) Color(s) | SLATE | |||||||||||||||||||
b) Print | ALPHA WIRE-* P/N 80053 4C 14 AWG RU AWM STYLE 21959 90C 600V SUN RES 60C OIL OR CRU AWM I/II A/B 90C 600V FT2 --- IEC EN 60332-1/2 CE ROHS (SEQ FOOTAGE) * = Factory Code |
1) UL | ||
a) Component 1 | AWM/STYLE 11231 | 105°C / 600 VRMS |
b) Overall | AWM/STYLE 21959 | 90°C / 600 VRMS |
60C OIL | ||
SUN RES | ||
2) CSA International | C(RU) AWM I/II A/B | 90°C / 600 VRMS |
FT2 | ||
3) IEC | ||
a) Component 1 | EN 60228 Conductors, Class 6 | |
b) Overall | EN 60754-1 Acid Gas Generation | |
EN 60754-2 Acid Gas Generation | ||
EN 60332-1 Flame Behavior | ||
EN 60332-2 Flame Behavior | ||
4) Other | NFPA 79 - 2015 Compliant | |
5) CE: | EU Low Voltage Directive 2014/35/EU |
1) CE: EU Directive 2011/65/EU(RoHS2), EU Directive 2015/863/EU (RoHS3): | ||
This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011 and the amending Directive 2015/863/EU of 4 June 2015 . No Exemptions are required for RoHS Compliance on this item. | ||
2) REACH Regulation (EC 1907/2006): | ||
This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item. |
Physical & Mechanical Properties | |
---|---|
1) Temperature Range | -50 to 90°C(static), -40 to 80°C (dynamic) |
2) Bend Radius | 4X Cable Diameter(static), 6X Cable Diameter(dynamic) |
3) Pull Tension | 131 Lbs, Maximum |
4) Sunlight Resistance | Yes |
Electrical Properties | (For Engineering purposes only) |
1) Voltage Rating | 600 VRMS |
2) Capacitance | 23.2 pF/ft @1 kHz, Nominal Conductor to Conductor |
3) Inductance | 0.15 μH/ft, Nominal |
4) Conductor DCR | 2.8 Ω/1000ft @20°C, Nominal |
Packaging | Flange x Traverse x Barrel (inches) |
a) 100 FT | 10.5 x 5 x 3.5 Continuous length |
b) Bulk(Made-to-order) | |
[Spool dimensions may vary slightly] |