Coaxial CableM4154
Alpha Wire offers 50-, 75-, 93-, and 100-ohm coaxial, twinaxial, and triaxial cables in a wide range of insulation and jacket materials and rated for UL, CSA and military specifications.
We now also provide non-magnetic coaxial cable options 9849 and 9851, which provide better signal transmission with minimal distortion while handling higher frequencies.
Looking for a space-saving option? We also offer Micro Coaxial cable, ideal for customers looking for uninterrupted signal transmission in compact spaces.
Diameter ("in") | ||||||||||||||
1) Component 1 | 2 x 1 COAX | |||||||||||||
a) Conductor | 20 (7/28) AWG TC | 0.038 | ||||||||||||
b) Insulation | 0.019" Wall, Nom. Polyethylene (PE) | 0.076 | ||||||||||||
(1) Color(s) | ||||||||||||||
|
||||||||||||||
2) Cable Assembly | 2 Components Cabled | |||||||||||||
a) Twists | 4.0 Twists/ft. (min.) | |||||||||||||
3) Shield | Alum/Mylar Tape, 25% Overlap (min.) | |||||||||||||
a) Foil Direction | Foil Facing Out | |||||||||||||
b) Drain Wire | 20 (7/28) AWG TC | |||||||||||||
c) Braid | TC, 55% Coverage (min.) | |||||||||||||
4) Jacket | 0.031" Wall, Nom., PVC | 0.238+/- 0.003 | ||||||||||||
a) Color(s) | BLUE | |||||||||||||
b) Print | ALPHA WIRE-* P/N M4154 1PR20 SHIELDED EXXXXX 75C (UL) CM OR AWM 2464 OR C(UL) TYPE CM CE ROHS * = Factory Code Note: Product may have c(UL) or CSA markings depending upon plant of manufacture. |
1) UL | CM | 75°C |
AWM/STYLE 2464 | 80°C / 300 VRMS | |
2) CSA International | C(UL) TYPE CM | 75°C |
3) CE | EU Low Voltage Directive 2006/95/EC |
1) CE: EU Directive 2011/65/EU(RoHS2) | ||
This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011. No exemptions are required for RoHS Compliance on this item. Refer to the RoHS Certificate of Compliance for more information. | ||
2) REACH Regulation (EC 1907/2006) | ||
This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, please see Alpha's REACH SVHC Declaration. | ||
3) California Proposition 65 | Outer surface materials used in manufacturing this part meet the requirements of California Proposition 65. |
Physical & Mechanical Properties | |
---|---|
1) Temperature Range | -20 to 80°C |
2) Bend Radius | 10X Cable Diameter |
3) Pull Tension | 28 lbs. max. |
Electrical Properties | Engineering purposes only |
1) Voltage Rating | 300 VRMS |
2) Characteristic Impedance | 78 Ω +/- 3 |
3) Inductance | 0.12 µH/ft., Nominal |
4) Mutual Capacitance | 19.7 pf/ft. @1 kHz, Nominal |
5) Ground Capacitance | 36 pf/ft. @1 kHz, Nominal |
6) Velocity of Propagation | 66 % |
7) Conductor DCR | 9.5 Ω/1000ft. @20°C, Nominal |
8) OA Shield DCR | 4.1 Ω/1000ft. @20°C, Nominal |
9) Attenuation (nom. dB/100ft.) | 0.6 @1 MHz |
2.1 @10 MHz | |
5@ 50 MHz | |
7.5 @100 MHz | |
11 @200 MHz | |
16 @400 MHz |
Packaging | Flange x Traverse x Barrel (inches) |
a) 1000 FT | 12 x 10 x 5 Continuous Length |
b) 500 FT | 12 x 4.5 x 3.5 Continuous Length |
c) 100 FT | 6.5 x 4 x 2.5 Continuous Length |
d) Bulk (made-to-order) | |
Spool dimensions may vary slightly. |