# de pieza Type  Shielding  Voltage  AWG  # of Elements  Jacket Diameter  Applicable Specifications 
45440/12 Conductor  FOIL  600/1000  16  12  0.649  CA Prop 65, CE, CSA AWM I/II A/B, CSA FT1, Pennsylvania Bureau of Mine Safety Approved, UL AWM 20238, UL TC, UL WTTC 
(Ctrl+Click if PDF doesn't appear)
 Diameters (In)
1) Component 1 12 X 1 COND 
a) Conductor 16 (19/.0117) AWG Tinned Copper 0.059
b) Insulation 0.032" Wall, Nom. TPE 0.123
(1) Color Code Alpha Wire Color Code E
Cond Color Cond Color Cond Color
1 BLACK 5 YELLOW9 SLATE
2 BROWN 6 GREEN10 WHITE
3 RED 7 BLUE11 WHITE/BLACK
4 ORANGE 8 VIOLET12 WHITE/BROWN
2) Cable Assembly 12 Components Cabled 
a) Twists: 2.0 Twists/foot (min) 
b) Core Wrap Nonwoven Polyester Tape, 25% Overlap, Min. 
3) Shield: Alum/Mylar Tape, 25% Overlap, Min. 
a) Foil Direction Foil Facing In 
b) Drain Wire 16 (19/.0117) AWG Tinned Copper 
4) Jacket 0.065" Wall, Nom.,TPE0.649 (0.678 Max.)
a) Color(s) Slate, Black, Yellow, Orange, Blue, Green, Red, Sand Beige, White
b) Ripcord 1 End 810 Denier Nylon 
c) Print ALPHA WIRE-* P/N 45440/12 12C 16 AWG
XTRAGUARD(R) 4 E324185 (UL) TYPE WTTC 90C DRY
1000V OR (UL) TYPE TC 90C DRY 600V OR AWM 20238
125C 600V 16 AWG OR CRU AWM I/II A/B
125C 600V FT1 P-07-KA140023-MSHA CE
(SEQ FOOTAGE)
* = Factory Code
1) UL AWM/STYLE 20238 125°C / 600 VRMS
 TC 90°C / 600 VRMS
 WTTC 90°C / 1000 VRMS
2) CSA International C(RU) AWM I/II A/B FT1 125°C / 600 VRMS
3) Other PENNSYLVANIA BUREAU OF MINE SAFETY APPROVED 
4) CE:EU Low Voltage Directive 2006/95/EC
1) California Proposition 65:The outer surface materials used in the manufacture of this part meet the requirements of California Proposition 65.
Physical & Mechanical Properties
1) Temperature Range-50 to 125°C
2) Bend Radius 10X Cable Diameter
3) Pull Tension 266 Lbs, Maximum
4) Sunlight Resistance Yes
Electrical Properties(For Engineering purposes only)
1) Voltage Rating 600/1000 VRMS
2) Capacitance 19.8 pf/ft @1 kHz, Nominal Conductor to Conductor
3) Ground Capacitance36 pf/ft @1 kHz, Nominal
4) Inductance0.2 µH/ft, Nominal
5) Conductor DCR4.4 Ω/1000ft @20°C, Nominal
6) OA Shield DCR3.5 Ω/1000ft @20°C, Nominal
PackagingFlange x Traverse x Barrel (inches)
a) Bulk(Made-to-order) 

Xtra-Guard® 4 - Apto para temperaturas extremas, tolera calor y frío High TemperatureLow TemperatureUltraviolet LightEMI Noise

    • Cable de temperatura extendida con un rango de temperatura que oscila entre -50 ºC y +125 ºC
    • Presenta aislamiento TPE de alto rendimiento y una cubierta exterior que triplican la flexibilidad a baja temperatura del PVC común
    • Resistencia moderada a aceites, solventes, sustancias químicas y combustibles
    • Excepcional estabilidad a la luz ultravioleta en todos los colores de cubierta exterior 
    • Calificación UL: 600 V TC y 300 V PLTC para aplicaciones de bandejas de cables (excepto 24 AWG)
    • Aprobado por la Pennsylvania Bureau Deep Mining Safety (Oficina de Seguridad en Minas Profundas de Pensilvania) para sistemas de control que abarcan toda la mina
    • Brinda protección excepcional contra la interferencia electromagnética cuando se especifica Supra-Shield

Solicite una muestra Descargar el catálogo Consultar a un experto

¿Necesita un diseño más personalizado?

Solicite un presupuesto personalizado Recursos
AlphaWire