Part # Voltage  # of Elements  AWG  Stranding  Insulation Thickness  Nominal Diameter  Insulation Material  Applicable Specifications 
3550/14 150/600  14  26  7/34  0.01  0.546 x 0.039  PVC  MIL-W-16878/1 Type B, UL AWM 2713, UL VW-1 
(Ctrl+Click if PDF doesn't appear)
 Diameters (In)
1) Component 1 14 X 1 COND 
a) Conductor 26 (7/34) AWG TC 0.019
b) Insulation 0.010" Wall, Nom. PVC 0.039
(1) Color(s)  
Cond Color Cond Color Cond Color
1 BROWN 6 BLUE11 BROWN
2 RED 7 VILOET12 RED
3 ORANGE 8 SLATE13 ORANGE
4 YELLOW 9 WHITE14 YELLOW
5 GREEN 10 BLACK 
2) Cable Assembly 14 Components assembled parallel.0.039 +/- 0.002 x
  0.546 +/- 0.028
1) UL AWM/STYLE 2713 80°C / 150 VRMS
 VW-1 
2) Military   
a) Component 1 MIL-DTL-16878/1 (Type B) 105°C / 600 VRMS
1) EU Directive 2011/65/EU(RoHS2):
 All materials used in the manufacture of this part are in compliance with European Directive 2011/65/EU and the amending Directive 2015/863/EU of 4 June 2015 regarding the restriction of use of certain hazardous substances in electrical and electronic equipment.
2) REACH Regulation (EC 1907/2006):
 This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item.
3) California Proposition 65:Exempt from warning labels based on the Consent Judgment. Please see Alpha's CA Prop 65 Statement for more information.
Physical & Mechanical Properties
1) Temperature Range-55 to 105°C
2) Bend Radius 10X Cable Diameter
3) Pull Tension 31 Lbs, Maximum
Electrical Properties(For Engineering purposes only)
1) Voltage Rating 600 VRMS
2) Capacitance 28 pf/ft @1 kHz, Nominal Conductor to Conductor
3) Inductance0.2 µH/ft, Nominal
4) Conductor DCR41 Ω/1000ft @20°C, Nominal
PackagingFlange x Traverse x Barrel (inches)
a) 100 FT 11 x 0.75 x 3 Continuous length
 [Spool dimensions may vary slightly]