Part # Voltage  AWG  Stranding  Insulation Thickness  Nominal Diameter  Insulation Material  Applicable Specifications 
3055 300  18  16/30  0.016  0.079  PVC  CA Prop 65, CSA FT1, CSA TR 64, UL AWM 1007, UL AWM 1569, UL VW-1 
(Ctrl+Click if PDF doesn't appear)
  Diameters (In)
1) Component 1 1 X 1 HOOKUP  
a) Conductor 18 (16/30) AWG Tinned Copper 0.047
b) Insulation 0.016" Wall, Nom. PVC 0.079+/- 0.002
(1) Print ALPHA WIRE E163869-* RU AWM STYLES 1569 105C
OR 1007 80C 300V VW-1 IEC 60332-1 18 AWG
OR CRU TR-64 90C FT1 CE ROHS
{0} * = Factory Code
[Note: Production prior to October 1st 2019 has below print legend.]
        ALPHA WIRE E163869-* RU AWM STYLES 1569 105C
        OR 1007 80C VW-1 300V 18 AWG ---- LXXXX CSA
        TR-64 90C FT1   ROHS

(2) Color(s) WHITE, BLACK, RED, GREEN, YELLOW, BLUE, BROWN
ORANGE, SLATE, VIOLET, WHITE/BLACK, WHITE/RED
WHITE/GREEN, WHITE/YELLOW, WHITE/BLUE
WHITE/BROWN, WHITE/ORANGE, WHITE/SLATE
WHITE/VIOLET, GREEN/YELLOW, YELLOW/GREEN, PINK, DK BLUE
1) UL AWM/STYLE 1007 80°C / 300 VRMS
  AWM/STYLE 1569 105°C / 300 VRMS
  VW-1  
2) CSA International TR-64 90°C
  FT1  
3) IEC EN 60332-1 Flame Behavior  
4) CE: EU Low Voltage Directive 2014/35/EU
1) EU Directive 2011/65/EU(RoHS2), EU Directive 2015/863/EU (RoHS3):
  All materials used in the manufacture of this part are in compliance with European Directive 2011/65/EU and the amending Directive 2015/863/EU of 4 June 2015 regarding the restriction of use of certain hazardous substances in electrical and electronic equipment. Consult Alpha Wire's web site for RoHS C of C.
2) REACH Regulation (EC 1907/2006):
  This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, please see Alpha's REACH SVHC Declaration.
3) California Proposition 65: Exempt from warning labels based on the Consent Judgment. Please see Alpha's CA Prop 65 Statement for more information.
Physical & Mechanical Properties
1) Temperature Range -40 to 105°C
2) Bend Radius 10X Cable Diameter
3) Pull Tension 12.6 Lbs, Maximum
Electrical Properties (For Engineering purposes only)
1) Voltage Rating 300 VRMS
2) Inductance 0.05 μH/ft, Nominal
3) Conductor DCR 7 Ω/1000ft @20°C, Nominal
Packaging Flange x Traverse x Barrel (inches)
a) 25000 DR 23 x 30 x 0 Max. 3 separate pieces; Min length/piece 5000 FT.
b) 5000 FT 12 x 6 x 3.5 Continuous length
c) 1000 FT UK 6.5 x 4 x 2.5 Continuous length
d) 1000 FT 6.5 x 4 x 2.5 Continuous length
e) 100 FT 3.5 x 3 x 1.125 Continuous length
  [Spool dimensions may vary slightly]
Notes:
a) Certain color and put-up combinations may only be available by special order. Minimums may apply.

Hook-Up Wire:

The broad range of hook-up wire from Alpha means you will find the product exactly suited to your application— whether it’s as straightforward as a control cabinet in a protected environment or as specialized as a machine tool on the factory floor, a high-temperature oven, or off-road construction equipment.

Our hook-up wire is available in a variety of insulations to meet your needs for temperature, ability to withstand wear and abrasion, electrical performance, or resistance to oil, solvents, and chemicals.

Request a Sample Download Brochure Consult a Cable Expert

Need a more unique construction? Different color code? Different color Jacket?

Request a Custom Quote Resources
AlphaWire