Part # Shielding  Voltage  AWG  # of Elements  Jacket Diameter  Flex Type  Applicable Specifications 
86602CY SupraShield (Premium Foil/Braid)  300  24  0.26  Continuous Flex Data  CA Prop 65, CE, CSA AWM I/II A/B, CSA CMG, CSA FT4, UL AWM 10002, UL AWM 2661, UL CM 
(Ctrl+Click if PDF doesn't appear)
 Diameters (In)
1) Component 1 2 X 1 PAIR 
a) Conductor 24 (10/34) AWG Tinned Copper 0.024
b) Insulation 0.010" Wall, Nom. PVC, Semi Rigid 0.044
(1) Color Code Alpha Wire Color Code A
Pair Color Pair Color Pair Color
1 BLACK-RED 2 BLACK-WHITE 
c) Pair 2/Cond Cabled Together 
(1) Twists: 9.6 Twists/foot (min) 
2) Cable Assembly 2 Components Cabled 
a) Twists: 8.0 Twists/foot (min) 
b) Orientation: Components to be arranged from INSIDE LAYER to OUTSIDE LAYER 
c) Core Wrap Nonwoven Polyester Tape, 25% Overlap, Min. 
3) Shield: Flex Alum/Mylar Tape, 25% Overlap, Min. 
a) Foil Direction Foil Facing Out 
b) Drain Wire 26 (7/34) AWG Tinned Copper 
c) Braid Tinned Copper,85% Coverage, Min. 
4) Jacket 0.040" Wall, Nom.,PVC0.260+/- 0.013
a) Color(s) SLATE
b) Jacket Separator Tissue Tape, 25% Overlap, Min. 
c) Print ALPHA WIRE-* P/N 86602CY 2PR 24 AWG
XTRAGUARD(R) CONTINUOUS FLEX DATA CABLE
(UL) 105C TYPE CM --- C(UL) CMG OR AWM 2661 105C
300V OR AWM 21894 105C 300V SUN RES 60C OIL ---
LLXXXXXX CSA AWM I/II A/B FT4 105C
300V CE ROHS (SEQ FOOTAGE)
* = Factory Code
[Note: Product may have c(UL) or CSA markings depending upon plant of manufacture.]
1) UL   
a) Component 1 AWM/STYLE 10002 105°C / 300 VRMS
b) Overall AWM/STYLE 2661 105°C / 300 VRMS
 CM 105°C
 AWM/STYLE 21894 105°C / 300 VRMS
 SUN RES 
 60C OIL 
2) CSA International AWM I/II A/B 105°C / 300 VRMS
 C(UL) TYPE CMG 105°C
 FT4 
3) CE:EU Low Voltage Directive 2014/35/EU
1) CE: EU Directive 2011/65/EU(RoHS2), EU Directive 2015/863/EU (RoHS3):
 This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011 and the amending Directive 2015/863/EU of 4 June 2015 . No Exemptions are required for RoHS Compliance on this item.
2) REACH Regulation (EC 1907/2006):
 This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item.
3) California Proposition 65:Exempt from warning labels based on the Consent Judgment. Please see Alpha's CA Prop 65 Statement for more information.
Physical & Mechanical Properties
1) Temperature Range-10 to 105°C(static), +5 to 105°C (dynamic)
2) Bend Radius 10X Cable Diameter(static), 15X Cable Diameter(dynamic)
3) Pull Tension 19.3 Lbs, Maximum
4) Sunlight Resistance Yes
Electrical Properties(For Engineering purposes only)
1) Voltage Rating 300 VRMS
2) Mutual Capacitance28 pF/ft @1 kHz, Nominal
3) Ground Capacitance50 pF/ft @1 kHz, Nominal
4) Characteristic Impedance64 Ω
5) Inductance0.19 µH/ft, Nominal
6) Conductor DCR30 Ω/1000ft @20°C, Nominal
7) OA Shield DCR3.8 Ω/1000ft @20°C, Nominal
PackagingFlange x Traverse x Barrel (inches)
a) 1000 FT 12 x 12 x 3.5 Continuous length
b) 500 FT 12 x 6 x 3.5 Continuous length
c) 100 FT 12 x 4.5 x 3.5 Continuous length
 [Spool dimensions may vary slightly]

Xtra-Guard® Flex - Wide variety of flexing applications Oil, Chemicals, Solvents, FuelsAbrasionEMI NoiseFlexing

  • Long-lasting flex cables designed to provide excellent performance in high-flex, high torsion, and continuous-flex applications, such as motion control and robotics
  • Rated for up to 14 million flex life cycles (85000 series), up to 6 Million flex life cycles (86000 series), & 1 Million for 65000 series
  • Available in a variety of configurations allowing exactly the right cable to be selected for the application
  • Rounded geometry helps ensure liquid-tight installations per IP67 or NEMA 6, when used with an appropriate connector or fitting
  • Supra-Shield provides precise EMI interference resistance for your specific application is easily achievable with the available standard flex, torsional flex, and continuous flex applications
  • Meets NFPA Standard 79 for industrial machinery*

*Product must be used in accordance with the respective AWM style. Click here for more details.

Request a Sample Download Brochure Consult a Cable Expert

Need a more unique construction? Different color code? Different color Jacket?

Request a Custom Quote Resources
AlphaWire