Part # Type  Shielding  Voltage  AWG  # of Elements  Jacket Diameter  Applicable Specifications 
45430/2 Conductor  FOIL  600/1000  18  0.34  CA Prop 65, CE, CSA AWM I/II A/B, CSA FT1, Pennsylvania Bureau of Mine Safety Approved, UL AWM 20238, UL TC, UL WTTC 
(Ctrl+Click if PDF doesn't appear)
 Diameters (In)
1) Component 1 2 X 1 COND 
a) Conductor 18 (16/30) AWG Tinned Copper 0.047
b) Insulation 0.032" Wall, Nom. TPE 0.111
(1) Color Code Alpha Wire Color Code E
Cond Color Cond Color Cond Color
1 BLACK 2 BROWN 
2) Cable Assembly 2 Components Cabled 
a) Twists: 4.8 Twists/foot (min) 
b) Core Wrap Nonwoven Polyester Tape, 25% Overlap, Min. 
3) Shield: Alum/Mylar Tape, 25% Overlap, Min. 
a) Foil Direction Foil Facing In 
b) Drain Wire 18 (16/30) AWG Tinned Copper 
4) Jacket 0.055" Wall, Nom.,TPE0.340 (0.357 Max.)
a) Color(s) Slate, Black, Yellow, Orange, Blue, Green, Red, Sand Beige, White
b) Ripcord 1 End 810 Denier Nylon 
c) Print ALPHA WIRE-* P/N 45430/2 2C 18 AWG
XTRAGUARD(R) 4 E324185 (UL) TYPE WTTC 90C DRY
1000V OR (UL) TYPE TC 90C DRY 600V OR AWM 20238
125C 600V 18 AWG OR CRU AWM I/II A/B
125C 600V FT1 P-07-KA140023-MSHA CE
(SEQ FOOTAGE)
* = Factory Code
1) UL AWM/STYLE 20238 125°C / 600 VRMS
 TC 90°C / 600 VRMS
 WTTC 90°C / 1000 VRMS
2) CSA International C(RU) AWM I/II A/B FT1 125°C / 600 VRMS
3) Other PENNSYLVANIA BUREAU OF MINE SAFETY APPROVED 
4) CE:EU Low Voltage Directive 2006/95/EC
1) California Proposition 65:The outer surface materials used in the manufacture of this part meet the requirements of California Proposition 65.
Physical & Mechanical Properties
1) Temperature Range-50 to 125°C
2) Bend Radius 10X Cable Diameter
3) Pull Tension 38 Lbs, Maximum
4) Sunlight Resistance Yes
Electrical Properties(For Engineering purposes only)
1) Voltage Rating 600/1000 VRMS
2) Capacitance 19 pf/ft @1 kHz, Nominal Conductor to Conductor
3) Ground Capacitance34 pf/ft @1 kHz, Nominal
4) Characteristic Impedance83 Ω
5) Inductance0.22 µH/ft, Nominal
6) Conductor DCR7.2 Ω/1000ft @20°C, Nominal
7) OA Shield DCR6.1 Ω/1000ft @20°C, Nominal
PackagingFlange x Traverse x Barrel (inches)
a) Bulk(Made-to-order) 

Xtra-Guard® 4 - Handles extreme hot and cold temperatures High TemperatureLow TemperatureUltraviolet LightEMI Noise

  • Extended-temperature cable with a temperature range from -50°C to +125°C
  • Features a high-performance TPE insulation and jacket offering three times the low-temperature flexibility of ordinary PVC
  • Outstanding ultraviolet light stability in all jacket colors
  • UL Rated TC 600 V and PLTC 300 V for cable tray applications (except 24 AWG)
  • Pennsylvania Bureau Deep Mining Safety approved for mine-wide monitoring systems
  • Provides exceptional protection against EMI interference when Supra-Shield is specified

Request a Sample Download Brochure Consult a Cable Expert

Need a more unique construction? Different color code? Different color Jacket?

Request a Custom Quote Resources
AlphaWire