Part # Type  Shielding  Voltage  AWG  # of Elements  Jacket Diameter  Applicable Specifications 
35199/50 Conductor  FOIL  300  22  50  0.479  CA Prop 65 
(Ctrl+Click if PDF doesn't appear)
 Diameters (In)
1) Component 1 50 X 1 COND 
a) Conductor 22 (7/30) AWG Tinned Copper 0.030
b) Insulation 0.010" Wall, Nom. PVC, Semi Rigid 0.050
(1) Color Code Alpha Wire Color Code E
Cond Color Cond Color Cond Color
1 BLACK 18 WHITE/VIOLET35 WHITE/RED/ORANGE
2 BROWN 19 WHITE/SLATE36 WHITE/RED/YELLOW
3 RED 20 WHITE/BLACK/BROWN37 WHITE/RED/GREEN
4 ORANGE 21 WHITE/BLACK/RED38 WHITE/RED/BLUE
5 YELLOW 22 WHITE/BLACK/ORANGE39 WHITE/RED/VIOLET
6 GREEN 23 WHITE/BLACK/YELLOW40 WHITE/RED/SLATE
7 BLUE 24 WHITE/BLACK/GREEN41 WHITE/ORANGE/YELLOW
8 VIOLET 25 WHITE/BLACK/BLUE42 WHITE/ORANGE/GREEN
9 SLATE 26 WHITE/BLACK/VIOLET43 WHITE/ORANGE/BLUE
10 WHITE 27 WHITE/BLACK/SLATE44 WHITE/ORANGE/VIOLET
11 WHITE/BLACK 28 WHITE/BROWN/RED45 WHITE/ORANGE/SLATE
12 WHITE/BROWN 29 WHITE/BROWN/ORANGE46 WHITE/YELLOW/GREEN
13 WHITE/RED 30 WHITE/BROWN/YELLOW47 WHITE/YELLOW/BLUE
14 WHITE/ORANGE 31 WHITE/BROWN/GREEN48 WHITE/YELLOW/VIOLET
15 WHITE/YELLOW 32 WHITE/BROWN/BLUE49 WHITE/YELLOW/SLATE
16 WHITE/GREEN 33 WHITE/BROWN/VIOLET50 WHITE/GREEN/BLUE
17 WHITE/BLUE 34 WHITE/BROWN/SLATE 
2) Cable Assembly 50 Components Cabled 
a) Twists: 2.0 Twists/foot (min) 
b) Orientation: Components to be arranged from INSIDE LAYER to OUTSIDE LAYER 
c) Core Wrap Clear Mylar Tape, 25% Overlap, Min. 
3) Shield: Alum/Mylar Tape, 25% Overlap, Min. 
a) Foil Direction Foil Facing In 
b) Drain Wire 22 (7/30) AWG Tinned Copper 
4) Jacket 0.032" Wall, Nom.,Polyethylene (PE)0.479 (0.504 Max.)
a) Color(s) Slate, Black, Yellow, Orange, Blue, Green, Red, Sand Beige, White
b) Ripcord 1 End 810 Denier Nylon 
c) Print ALPHA WIRE-* P/N 35199/50 50C 22 AWG
XTRAGUARD(R) 3 80C 300 VOLTS CE ROHS
(SEQ FOOTAGE)
* = Factory Code
1) CE:EU Low Voltage Directive 2014/35/EC
1) CE: EU Directive 2011/65/EU(RoHS2), EU Directive 2015/863/EU (RoHS3):
 This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011 and the amending Directive 2015/863/EU of 4 June 2015 . No Exemptions are required for RoHS Compliance on this item. Consult Alpha Wire's web site for RoHS C of C.
2) REACH Regulation (EC 1907/2006):
 This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, please see Alpha's REACH SVHC Declaration.
3) California Proposition 65:Exempt from warning labels based on the Consent Judgment. Please see Alpha's CA Prop 65 Statement for more information.
Physical & Mechanical Properties
1) Temperature Range-30 to 80°C
2) Bend Radius 10X Cable Diameter
3) Pull Tension 280 Lbs, Maximum
4) Sunlight Resistance Yes
5) Direct Burial Yes
Electrical Properties(For Engineering purposes only)
1) Voltage Rating 300 VRMS
2) Capacitance 36 pF/ft @1 kHz, Nominal Conductor to Conductor
3) Ground Capacitance65 pF/ft @1 kHz, Nominal
4) Inductance0.18 µH/ft, Nominal
5) Conductor DCR16.5 Ω/1000ft @20°C, Nominal
6) OA Shield DCR9.2 Ω/1000ft @20°C, Nominal
PackagingFlange x Traverse x Barrel (inches)
a) Bulk(Made-to-order) 

Xtra-Guard® 3 - Direct burial—no conduit needed Ultraviolet LightOil, Chemicals, Solvents, FuelsDirect BurialEMI Noise

  • The preferred outdoor cable for direct burial
  • 6 times the water resistance of PVC
  • Features a specially formulated polyethylene jacket for outstanding service life and ultraviolet light stability in all jacket colors
  • Resistant to the effects of weathering, moisture, and UV aging without the costly use of conduit
  • Supra-Shield® provides exceptional protection against conducted or electrical noise in high- and low- frequency environments where EMI interference is pervasive

Request a Sample Download Brochure Consult a Cable Expert

Need a more unique construction? Different color code? Different color Jacket?

Request a Custom Quote Resources
AlphaWire