Part # Type  Shielding  Voltage  AWG  # of Elements  Jacket Diameter  Applicable Specifications 
5199/70C Conductor  FOIL  300  22  70  0.606  CA Prop 65, CE, CSA CMG, CSA FT4, IEC 60332-1, IEC 60332-2, UL 60C OIL, UL AWM 10002, UL AWM 2464, UL CM, UL SUN RES, UL VW-1 
(Ctrl+Click if PDF doesn't appear)
 Diameters (In)
1) Component 1 70 X 1 COND 
a) Conductor 22 (7/30) AWG Tinned Copper 0.030
b) Insulation 0.010" Wall, Nom. PVC, Semi Rigid 0.050
(1) Color Code Alpha Wire Color Code E
Cond Color Cond Color Cond Color
1 BLACK 25 WHITE/BLACK/BLUE49 WHITE/YELLOW/SLATE
2 BROWN 26 WHITE/BLACK/VIOLET50 WHITE/GREEN/BLUE
3 RED 27 WHITE/BLACK/SLATE51 WHITE/GREEN/VIOLET
4 ORANGE 28 WHITE/BROWN/RED52 WHITE/GREEN/SLATE
5 YELLOW 29 WHITE/BROWN/ORANGE53 WHITE/BLUE/VIOLET
6 GREEN 30 WHITE/BROWN/YELLOW54 WHITE/BLUE/SLATE
7 BLUE 31 WHITE/BROWN/GREEN55 WHITE/VIOLET/SLATE
8 VIOLET 32 WHITE/BROWN/BLUE56 WHITE/BLACK/BROWN/RED
9 SLATE 33 WHITE/BROWN/VIOLET57 WHITE/BLACK/BROWN/ORANGE
10 WHITE 34 WHITE/BROWN/SLATE58 WHITE/BLACK/BROWN/YELLOW
11 WHITE/BLACK 35 WHITE/RED/ORANGE59 WHITE/BLACK/BROWN/GREEN
12 WHITE/BROWN 36 WHITE/RED/YELLOW60 WHITE/BLACK/BROWN/BLUE
13 WHITE/RED 37 WHITE/RED/GREEN61 WHITE/BLACK/BROWN/VIOLET
14 WHITE/ORANGE 38 WHITE/RED/BLUE62 WHITE/BLACK/BROWN/SLATE
15 WHITE/YELLOW 39 WHITE/RED/VIOLET63 WHITE/BLACK/RED/YELLOW
16 WHITE/GREEN 40 WHITE/RED/SLATE64 WHITE/BLACK/RED/GREEN
17 WHITE/BLUE 41 WHITE/ORANGE/YELLOW65 WHITE/BLACK/RED/BLUE
18 WHITE/VIOLET 42 WHITE/ORANGE/GREEN66 WHITE/BLACK/RED/VIOLET
19 WHITE/SLATE 43 WHITE/ORANGE/BLUE67 WHITE/BLACK/RED/SLATE
20 WHITE/BLACK/BROWN 44 WHITE/ORANGE/VIOLET68 WHITE/BLACK/ORANGE/YELLOW
21 WHITE/BLACK/RED 45 WHITE/ORANGE/SLATE69 WHITE/BLACK/ORANGE/GREEN
22 WHITE/BLACK/ORANGE 46 WHITE/YELLOW/GREEN70 WHITE/BLACK/ORANGE/BLUE
23 WHITE/BLACK/YELLOW 47 WHITE/YELLOW/BLUE 
24 WHITE/BLACK/GREEN 48 WHITE/YELLOW/VIOLET 
2) Cable Assembly 70 Components Cabled 
a) Twists: 2.1 Twists/foot (min) 
b) Orientation: Components to be arranged from INSIDE LAYER to OUTSIDE LAYER 
c) Core Wrap Nonwoven Polyester Tape, 25% Overlap, Min. 
3) Shield: Alum/Mylar Tape, 25% Overlap, Min. 
a) Foil Direction Foil Facing In 
b) Drain Wire 22 (7/30) AWG Tinned Copper 
4) Jacket 0.053" Wall, Nom.,PVC0.606 (0.638 Max.)
a) Color(s) Slate, Black, Yellow, Orange, Blue, Green, Red, Sand Beige, White
b) Ripcord 1 End 810 Denier Nylon 
c) Print ALPHA WIRE-* P/N 5199/70C 70C 22 AWG
XTRAGUARD(R) 1 SHIELDED (UL) TYPE CM 105C OR AWM
2464 80C 300V OR AWM 21894 105C 300V SUN RES 60C
OIL VW-1 --- LLXXXXXX CSA 105C TYPE CMG FT4
CE ROHS (SEQ FOOTAGE)
* = Factory Code
[Note: Product may have c(UL) or CSA markings depending upon plant of manufacture.]
1) UL   
a) Component 1 AWM/STYLE 10002 105°C / 300 VRMS
b) Overall AWM/STYLE 21894 105°C / 300 VRMS
 SUN RES 
 60C OIL 
 AWM/STYLE 2464 80°C / 300 VRMS
 CM 105°C
 VW-1 
2) CSA International CMG 105°C
 FT4 
3) IEC EN 60332-1 Flame Behavior 
 EN 60332-2 Flame Behavior 
4) CE:EU Low Voltage Directive 2014/35/EC
1) CE: EU Directive 2011/65/EU(RoHS2), EU Directive 2015/863/EU (RoHS3):
 This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011 and the amending Directive 2015/863/EU of 4 June 2015 . No Exemptions are required for RoHS Compliance on this item. Consult Alpha Wire's web site for RoHS C of C.
2) REACH Regulation (EC 1907/2006):
 This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, please see Alpha's REACH SVHC Declaration.
3) California Proposition 65:Exempt from warning labels based on the Consent Judgment. Please see Alpha's CA Prop 65 Statement for more information.
Physical & Mechanical Properties
1) Temperature Range-35 to 105°C
2) Bend Radius 10X Cable Diameter
3) Pull Tension 390 Lbs, Maximum
4) Sunlight Resistance Yes
Electrical Properties(For Engineering purposes only)
1) Voltage Rating 300 VRMS
2) Capacitance 36 pF/ft @1 kHz, Nominal Conductor to Conductor
3) Ground Capacitance65 pF/ft @1 kHz, Nominal
4) Inductance0.18 µH/ft, Nominal
5) Conductor DCR16.7 Ω/1000ft @20°C, Nominal
6) OA Shield DCR8.4 Ω/1000ft @20°C, Nominal
PackagingFlange x Traverse x Barrel (inches)
a) 1000 FT 30 x 14 x 12 Continuous length
b) 500 FT 24 x 14 x 12 Continuous length
c) 100 FT 16 x 11 x 8 Continuous length
d) Bulk(Made-to-order) 
 [Spool dimensions may vary slightly]

Xtra-Guard® 1 - High performance in a tough PVC cable Ultraviolet LightEMI NoiseOil, Chemicals, Solvents, Fuels

  • High-performance cable for general-purpose applications
  • Features a unique, premium-grade PVC insulation and jacket for easier routing of cable in small spaces
  • Provides resistance to oils per UL Oil Res I (60C OIL RES) and Class 43
  • UL SUN RES
  • Designed for use in ambient temperatures up to 105 ° C
  • Temperature range of -35 ° C to + 105 ° C (SR-PVC) and -30 ° C to + 105 ° C (PVC)
  • Provides exceptional protection against EMI interference When Supra-Shield is specified


Request a Sample Download Brochure Consult a Cable Expert

Need a more unique construction? Different color code? Different color Jacket?

Request a Custom Quote Resources
AlphaWire