Part # AWG  Stranding  Construction Type  # of Elements  Shielding  Jacket Diameter  Temperature Range  Voltage  Applicable Specifications 
80102 28  19/40  COND  BRAID  0.174  -50 to 90  600  CA Prop 65, CE, CSA AWM I/II A/B, CSA FT2, IEC 60332-1, IEC 60332-2, IEC 60754-1, IEC 60754-2, IEC EN 60228 Conductors, Class 6, REACH Regulation (EC 1907/2006), ROHS - RoHS Compliance, UL 60C OIL, UL AWM 21959, UL SUN RES 
(Ctrl+Click if PDF doesn't appear)
 Diameters (In)
1) Component 1 3 X 1 COND 
a) Conductor 28 (19/40) AWG Tinned Copper 0.016
b) Insulation 0.010" Wall, Nom. MPPE 0.036
(1) Color Code Alpha Wire Color Code D
Cond Color Cond Color Cond Color
1 BLACK 2 RED3 WHITE
2) Cable Assembly 3 Components Cabled 
a) Twists: 13.7 Twists/foot (min) 
b) Orientation: Components to be arranged from INSIDE LAYER to OUTSIDE LAYER 
c) Core Wrap Nonwoven Polyester Tape, 25% Overlap, Min. 
3) Shield Tinned Copper BRAID Shield,85% Coverage, Min. 
4) Jacket 0.032" Wall, Nom.,Polyurethane, Zero Halogen (ZH)0.174+/- 0.010
a) Color(s) SLATE
b) Jacket Separator Tissue Tape, 25% Overlap, Min. 
c) Print ALPHA WIRE-* P/N 80102 3C 28 AWG
RU AWM STYLE 21959 90C 600V SUN RES 60C OIL OR
CRU AWM I/II A/B 90C 600V FT2 --- IEC EN 60332-1/2
CE ROHS (SEQ FOOTAGE)
* = Factory Code
1) UL   
a) Component 1 AWM/STYLE 11231 105°C / 600 VRMS
b) Overall AWM/STYLE 21959 90°C / 600 VRMS
 60C OIL 
 SUN RES 
2) CSA International C(RU) AWM I/II A/B 90°C / 600 VRMS
 FT2 
3) IEC   
a) Component 1 EN 60228 Conductors, Class 6 
b) Overall EN 60754-1 Acid Gas Generation 
 EN 60754-2 Acid Gas Generation 
 EN 60332-1 Flame Behavior 
 EN 60332-2 Flame Behavior 
4) Other NFPA 79 - 2015 Compliant 
5) CE:EU Low Voltage Directive 2014/35/EU
1) CE: EU Directive 2011/65/EU(RoHS2), EU Directive 2015/863/EU (RoHS3):
 This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011 and the amending Directive 2015/863/EU of 4 June 2015 . No Exemptions are required for RoHS Compliance on this item. Consult Alpha Wire's web site for RoHS C of C.
2) REACH Regulation (EC 1907/2006):
 This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, please see Alpha's REACH SVHC Declaration.
3) California Proposition 65:Exempt from warning labels based on the Consent Judgment. Please see Alpha's CA Prop 65 Statement for more information.
Physical & Mechanical Properties
1) Temperature Range-50 to 90°C(static), -40 to 80°C (dynamic)
2) Bend Radius 4X Cable Diameter(static), 6X Cable Diameter(dynamic)
3) Pull Tension 7 Lbs, Maximum
4) Sunlight Resistance Yes
Electrical Properties(For Engineering purposes only)
1) Voltage Rating 600 VRMS
2) Capacitance 18.6 pF/ft @1 kHz, Nominal Conductor to Conductor
3) Ground Capacitance33 pF/ft @1 kHz, Nominal
4) Inductance0.21 μH/ft, Nominal
5) Conductor DCR63 Ω/1000ft @20°C, Nominal
6) OA Shield DCR7.9 Ω/1000ft @20°C, Nominal
PackagingFlange x Traverse x Barrel (inches)
a) 100 FT 6.5 x 2 x 1.9 Continuous length
b) Bulk(Made-to-order) 
 [Spool dimensions may vary slightly]
Notes:
a) Products manufactured before 08/01/2016 will have the Alphawire KX color code. Please refer to http://www.alphawire.com/en/ResourceCenter/Tools/PartNoColorCodes for KX color code.

EcoFlex® PUR Continuous Flex Cable:

Get the abrasion, UV, and oil resistance of a tough zero-halogen Polyurethane jacket in a flex cable that’s up to 40% smaller and 44% lighter than other 600V continuous flex cables.

  • Zero Halogen, contains no heavy metals or phthalates
  • PUR jacket, mPPE insulation
  • 8M+ flex life cycles
  • finely stranded tinned copper conductors, class 6
  • Up to 40% smaller and 44% lighter than standard 600V PUR continuous flex cables
  • UL Oil Res I
  • UL Sunlight Resistant
  • Operating temperature -50C to +90C (static) and -40C to +80C (dynamic)
  • Bend Radius 4X (static) and 6X (dynamic)

With its rugged PUR jacket and finely stranded conductors, EcoFlex PUR cable provides 8+ million flex cycles in tough application conditions—while saving space and reducing weight. And with a wide range of conductor sizes, conductor counts, and shielded and unshielded versions, you can find the cable you need. 

Request a Sample Download Brochure Consult a Cable Expert

Need a more unique construction? Different color code? Different color Jacket?

Request a Custom Quote Resources
AlphaWire