Construction
| Diameters (In) |
1) Component 1 | 15 X 1 COND | |
a) Conductor | 24 (19/36) AWG Tinned Copper | 0.025 |
b) Insulation | 0.007" Wall, Nom. Modified Polyphenylene Ether-PE | 0.039 |
(1) Color Code | Alpha Wire Color Code E |
Cond | Color | Cond | Color | Cond | Color | 1 | BLACK | 6 | GREEN | 11 | WHITE/BLACK | 2 | BROWN | 7 | BLUE | 12 | WHITE/BROWN | 3 | RED | 8 | VIOLET | 13 | WHITE/RED | 4 | ORANGE | 9 | SLATE | 14 | WHITE/ORANGE | 5 | YELLOW | 10 | WHITE | 15 | WHITE/YELLOW |
|
2) Cable Assembly | 15 Components Cabled | |
a) Twists: | 4.8 Twists/foot (min) | |
b) Orientation: | Components to be arranged from INSIDE LAYER to OUTSIDE LAYER | |
c) Core Wrap | Nonwoven Polyester Tape, 25% Overlap, Min. | |
3) Shield: | Alum/Mylar Tape, 25% Overlap, Min. | |
a) Foil Direction | Foil Facing In | |
b) Drain Wire | 24 (7/32) AWG Tinned Copper | |
4) Jacket | 0.015" Wall, Nom.,Modified Polyphenylene Ether-PE | 0.217 (0.230 Max.) |
a) Color(s) | SLATE |
b) Ripcord | 1 End 810 Denier Nylon | |
c) Print | ALPHA WIRE-* P/N 78131 15C 24 AWG ECOCABLE(R) MINI RU AWM 21460 80C 300V VW-1 C(RU) AWM I A/B FT1 80C 300V CE ROHS (SEQ FOOTAGE) * = Factory Code
|
Applicable Specifications
1) UL | AWM/STYLE 21460 | 80°C / 300 VRMS |
| VW-1 | |
2) CSA International | C(RU) AWM I A/B FT1 | 80°C / 300 VRMS |
3) Other | Halogen-Free | |
| NFPA 79 - 2015 Compliant | |
4) CE: | EU Low Voltage Directive 2014/35/EC |
Environmental
1) CE: EU Directive 2011/65/EU(RoHS2): |
| This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011and the amending Directive 2015/863/EU of 4 June 2015 . No Exemptions are required for RoHS Compliance on this item. Consult Alpha Wire's web site for RoHS C of C. |
2) REACH Regulation (EC 1907/2006): |
| This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, please see Alpha's REACH SVHC Declaration. |
Properties
Physical & Mechanical Properties |
---|
1) Temperature Range | -40 to 80°C |
2) Bend Radius | 10X Cable Diameter |
3) Pull Tension | 59 Lbs, Maximum |
Electrical Properties | (For Engineering purposes only) |
---|
1) Voltage Rating | 300 VRMS |
2) Capacitance | 30 pF/ft @1 kHz, Nominal Conductor to Conductor
|
3) Ground Capacitance | 54 pF/ft @1 kHz, Nominal
|
4) Inductance | 0.17 µH/ft, Nominal
|
5) Conductor DCR | 24.3 Ω/1000ft @20°C, Nominal
|
6) OA Shield DCR | 15.9 Ω/1000ft @20°C, Nominal
|
Other
Packaging | Flange x Traverse x Barrel (inches) |
a) 1000 FT | 12 x 10 x 5 Continuous length |
b) 100 FT | 6.5 x 4 x 2.5 Continuous length |
c) Bulk(Made-to-order) | |
| [Spool dimensions may vary slightly] |
EcoCable® Mini 300 V Recyclable Cable:
EcoCable® Mini is the next generation of 300 V cables. By combining better performance and minimum environmental impact, EcoCable Mini uses its mPPE insulation and jacketing to provide all of the advantages in a smaller, lighter cable.
EcoCable Mini Features
- Recyclable mPPE jacket and insulation
- -40°C to +80°C temperature range
- RoHS and REACH Compliant
- Suitable for use in NFPA 79 applications
- Over 250 Standard Constructions available
|
EcoCable Mini Benefits
- Up to 32% smaller than PVC
- Up to 44% lighter than PVC
- Up to 92% lower outgassing than standard 300 V PVC cables
- Halogen Free
- 100% recyclable
|
Request a Sample
Download Brochure
Consult a Cable Expert
Need a more unique construction? Different color code? Different color Jacket?
Request a Custom Quote
Resources