Part # Type  Shielding  Voltage  AWG  # of Elements  Jacket Material  Jacket Diameter  Applicable Specifications 
M5372 Conductor  FOIL_BRAID  300  20  25  PVC  0.513  CA Prop 65, CSA CMG, CSA FT4, UL AWM 2464, UL CMG 
(Ctrl+Click if PDF doesn't appear)
 Diameters (In)
1) Component 1 25 X 1 COND 
a) Conductor 20 (7/28) AWG TC 0.038
b) Insulation 0.016" Wall, Nom. PVC 0.070
(1) Color Code Alpha Wire Color Code D
Cond Color Cond Color Cond Color
1 BLACK 10 SLATE19 WHITE/YELLOW
2 RED 11 PINK20 WHITE/BLUE
3 WHITE 12 TAN21 WHITE/BROWN
4 GREEN 13 RED/GREEN22 WHITE/ORANGE
5 ORANGE 14 RED/YELLOW23 WHITE/SLATE
6 BLUE 15 RED/BLACK24 WHITE/VIOLET
7 BROWN 16 WHITE/BLACK25 WHITE/BLACK/RED
8 YELLOW 17 WHITE/RED 
9 VIOLET 18 WHITE/GREEN 
2) Cable Assembly 25 Components Cabled 
a) Twists: 1.9 Twists/foot (min) 
b) Core Wrap Clear Mylar Tape, 25% Overlap, Min. 
3) Shield: Alum/Mylar Tape, 25% Overlap, Min. 
a) Foil Direction Foil Facing Out 
b) Drain Wire 20 (7/28) AWG TC 
c) Braid TC,70% Coverage, Min. 
4) Jacket 0.032" Wall, Nom.,PVC0.513 (0.534 Max.)
a) Color(s) SLATE
b) Ripcord 1 End 810 Denier Nylon 
c) Print ALPHA WIRE-* P/N M5372 25C 20 AWG
EXXXXXX SHIELDED 75C CMG (UL) C(UL) OR
AWM 2464 CE ROHS
* = Factory Code
[Note: Product may have c(UL) or CSA markings depending upon plant of manufacture.]
1) UL AWM/STYLE 2464 80°C / 300 VRMS
 CMG 75°C
2) CSA International FT4 
 C(UL) TYPE CMG 75°C
3) CE:EU Low Voltage Directive 2006/95/EC
1) CE: EU Directive 2011/65/EU(RoHS2), EU Directive 2015/863/EU (RoHS3):
 This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011 and the amending Directive 2015/863/EU of 4 June 2015 . No Exemptions are required for RoHS Compliance on this item. Consult Alpha Wire's web site for RoHS C of C.
2) REACH Regulation (EC 1907/2006):
 This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, please see Alpha's REACH SVHC Declaration.
3) California Proposition 65:Exempt from warning labels based on the Consent Judgment. Please see Alpha's CA Prop 65 Statement for more information.
Physical & Mechanical Properties
1) Temperature Range-20 to 80°C
2) Bend Radius 10X Cable Diameter
3) Pull Tension 236 Lbs, Maximum
Electrical Properties(For Engineering purposes only)
1) Voltage Rating 300 VRMS
2) Capacitance 44 pf/ft @1 kHz, Nominal Conductor to Conductor
3) Ground Capacitance79 pf/ft @1 kHz, Nominal
4) Inductance0.19 µH/ft, Nominal
5) Conductor DCR10.3 Ω/1000ft @20°C, Nominal
6) OA Shield DCR1.79 Ω/1000ft @20°C, Nominal
PackagingFlange x Traverse x Barrel (inches)
a) 1000 FT 24 x 14 x 12 Continuous length
b) 500 FT 20 x 11 x 8 Continuous length
c) 100 FT 16 x 11 x 8 Continuous length
d) Bulk(Made-to-order) 
 [Spool dimensions may vary slightly]

Communication and Control Cable:

Get Control Of Your Communication and Control Applications

Our line-up of standard communication and control cables gives you maximum choice and fewer tradeoffs. By offering you a comprehensive collection of insulation/jacketing materials, shielding options, and conductor counts, you can easily select the cable that meets your most demanding needs. We have cables that go beyond the ordinary to satisfy rigorous requirements of EMI performance, transmission distances, flexibility, and temperature extremes.

Communication and Control Typical applications:

  • Audio systems: speakers, microphones, intercoms

  • Broadcast and studio

  • Data transmission: RS-232, 422, 485

  • CAD/CAM

  • Computer peripherals

  • Business machines

  • Security systems: alarms, cameras, sensors

  • Control systems

  • Instrumentation systems

  • Point-of-sale systems

  • Banking systems

Low capacitance cables for improved transmission distances and signal integrity.

Request a Sample Download Brochure Consult a Cable Expert

Need a more unique construction? Different color code? Different color Jacket?

Request a Custom Quote Resources