Part # Type  Shielding  Voltage  AWG  # of Elements  Jacket Material  Jacket Diameter  Applicable Specifications 
M1114 Conductor  BRAID  300  22  PVC  0.22  CA Prop 65, NEC CM, UL AWM 2094 
(Ctrl+Click if PDF doesn't appear)
 Diameters (In)
1) Component 1 4 X 1 COND 
a) Conductor 22 (19/34) AWG Tinned Copper 0.032
b) Insulation 0.016" Wall, Nom. FRPE 0.064
(1) Color Code Alpha Wire Color Code H
Cond Color Cond Color Cond Color
1 BLACK 3 RED 
2 WHITE 4 GREEN 
2) Cable Assembly 4 Components Cabled 
a) Twists: 5.3 Twists/foot (min) 
b) Orientation: Components to be arranged from INSIDE LAYER to OUTSIDE LAYER 
c) Core Wrap Clear Mylar Tape, 25% Overlap, Min. 
3) Shield Tinned Copper BRAID Shield,90% Coverage, Min. 
4) Jacket 0.020" Wall, Nom.,PVC0.220 (0.231 Max.)
a) Color(s) SLATE
b) Print ALPHA WIRE-* P/N M1114 4C 22 AWG
EXXXXXX (UL) TYPE CM 75C OR AWM 2094
CE ROHS
* = Factory Code
1) UL CM 75°C
 AWM/STYLE 2094 60°C / 300 VRMS
2) CE:EU Low Voltage Directive 2014/35/EU
1) CE: EU Directive 2011/65/EU(RoHS2), EU Directive 2015/863/EU (RoHS3):
 This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011 and the amending Directive 2015/863/EU of 4 June 2015 . No Exemptions are required for RoHS Compliance on this item. Consult Alpha Wire's web site for RoHS C of C.
2) California Proposition 65:Exempt from warning labels based on the Consent Judgment. Please see Alpha's CA Prop 65 Statement for more information.
Physical & Mechanical Properties
1) Temperature Range-20 to 75°C
2) Bend Radius 10X Cable Diameter
3) Pull Tension 29 Lbs, Maximum
Electrical Properties(For Engineering purposes only)
1) Voltage Rating 300 VRMS
2) Capacitance 22.7 pF/ft @1 kHz, Nominal Conductor to Conductor
3) Ground Capacitance41 pF/ft @1 kHz, Nominal
4) Inductance0.2 µH/ft, Nominal
5) Conductor DCR15.2 Ω/1000ft @20°C, Nominal
6) OA Shield DCR3.8 Ω/1000ft @20°C, Nominal
PackagingFlange x Traverse x Barrel (inches)
a) 1000 FT 12 x 10 x 5 Continuous length
b) 500 FT 12 x 4.5 x 3.5 Continuous length
c) 100 FT 6.5 x 4 x 2.5 Continuous length
d) Bulk(Made-to-order) 
 [Spool dimensions may vary slightly]

Communication and Control Cable:

Get Control Of Your Communication and Control Applications

Our line-up of standard communication and control cables gives you maximum choice and fewer tradeoffs. By offering you a comprehensive collection of insulation/jacketing materials, shielding options, and conductor counts, you can easily select the cable that meets your most demanding needs. We have cables that go beyond the ordinary to satisfy rigorous requirements of EMI performance, transmission distances, flexibility, and temperature extremes.

Communication and Control Typical applications:

  • Audio systems: speakers, microphones, intercoms

  • Broadcast and studio

  • Data transmission: RS-232, 422, 485

  • CAD/CAM

  • Computer peripherals

  • Business machines

  • Security systems: alarms, cameras, sensors

  • Control systems

  • Instrumentation systems

  • Point-of-sale systems

  • Banking systems

Low capacitance cables for improved transmission distances and signal integrity.

Request a Sample Download Brochure Consult a Cable Expert

Need a more unique construction? Different color code? Different color Jacket?

Request a Custom Quote Resources
AlphaWire