Part # Type  Shielding  Voltage  AWG  # of Elements  Jacket Material  Jacket Diameter  Applicable Specifications 
2219/27C Pair  FOIL  150  22  27  PVC  0.589  CA Prop 65, CSA CMG, CSA FT4, UL AWM 2576, UL CM, UL VW-1 
(Ctrl+Click if PDF doesn't appear)
 Diameters (In)
1) Component 1 27 X 1 PAIR 
a) Conductor 22 (7/30) AWG TC 0.030
b) Insulation 0.010" Wall, Nom. PVC 0.050
(1) Color Code Alpha Wire Color Code A
Pair Color Pair Color Pair Color
1 BLACK-RED 10 RED-BLUE19 WHITE-BLUE
2 BLACK-WHITE 11 RED-YELLOW20 WHITE-BROWN
3 BLACK-GREEN 12 RED-BROWN21 WHITE-ORANGE
4 BLACK-BLUE 13 RED-ORANGE22 WHITE-YELLOW
5 BLACK-BROWN 14 GREEN-BLUE23 BLUE-BROWN
6 BLACK-YELLOW 15 GREEN-WHITE24 BLUE-ORANGE
7 BLACK-ORANGE 16 GREEN-BROWN25 BLUE-YELLOW
8 RED-GREEN 17 GREEN-ORANGE26 BROWN-ORANGE
9 RED-WHITE 18 GREEN-YELLOW27 BROWN-YELLOW
c) Pair 2/Cond Cabled Together 
(1) Twists: 8.0 Twists/foot (min) 
2) Cable Assembly 27 Components Cabled 
a) Twists: 1.6 Twists/foot (min) 
3) Shield: Alum/Mylar Tape, 25% Overlap, Min. 
a) Foil Direction Foil Facing Out 
b) Drain Wire 22 (7/30) AWG TC 
4) Jacket 0.040" Wall, Nom.,PVC0.589 (0.619 Max.)
a) Color(s) SLATE
b) Print ALPHA WIRE-* P/N 2219/27C 27PR 22 AWG
SHIELDED 75C (UL) TYPE CM OR AWM 2576 --- LLXXXXXX
CSA TYPE CMG FT4 CE ROHS
* = Factory Code
[Note: Product may have c(UL) or CSA markings depending upon plant of manufacture.]
1) UL AWM/STYLE 2576 80°C / 150 VRMS
 CM 75°C
 VW-1 
2) CSA International CMG 60°C
 FT4 
3) CE:EU Low Voltage Directive 2006/95/EC
1) CE: EU Directive 2011/65/EU(RoHS2), EU Directive 2015/863/EU (RoHS3):
 This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011 and the amending Directive 2015/863/EU of 4 June 2015 . No Exemptions are required for RoHS Compliance on this item.
2) REACH Regulation (EC 1907/2006):
 This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item.
3) California Proposition 65:Exempt from warning labels based on the Consent Judgment. Please see Alpha's CA Prop 65 Statement for more information.
Physical & Mechanical Properties
1) Temperature Range-20 to 80°C
2) Bend Radius 10X Cable Diameter
3) Pull Tension 302 Lbs, Maximum
Electrical Properties(For Engineering purposes only)
1) Voltage Rating 150 VRMS
2) Mutual Capacitance35 pf/ft @1 kHz, Nominal
3) Ground Capacitance63 pf/ft @1 kHz, Nominal
4) Characteristic Impedance65 Ω
5) Inductance0.18 µH/ft, Nominal
6) Conductor DCR16.6 Ω/1000ft @20°C, Nominal
7) OA Shield DCR8.3 Ω/1000ft @20°C, Nominal
PackagingFlange x Traverse x Barrel (inches)
a) 1000 FT 30 x 14 x 12 Continuous length
b) 500 FT 24 x 14 x 12 Continuous length
c) 100 FT 16 x 11 x 8 Continuous length
 [Spool dimensions may vary slightly]

Communication and Control Cable:

Get Control Of Your Communication and Control Applications

Our line-up of standard communication and control cables gives you maximum choice and fewer tradeoffs. By offering you a comprehensive collection of insulation/jacketing materials, shielding options, and conductor counts, you can easily select the cable that meets your most demanding needs. We have cables that go beyond the ordinary to satisfy rigorous requirements of EMI performance, transmission distances, flexibility, and temperature extremes.

Communication and Control Typical applications:

  • Audio systems: speakers, microphones, intercoms

  • Broadcast and studio

  • Data transmission: RS-232, 422, 485

  • CAD/CAM

  • Computer peripherals

  • Business machines

  • Security systems: alarms, cameras, sensors

  • Control systems

  • Instrumentation systems

  • Point-of-sale systems

  • Banking systems

Low capacitance cables for improved transmission distances and signal integrity.

Request a Sample Download Brochure Consult a Cable Expert

Need a more unique construction? Different color code? Different color Jacket?

Request a Custom Quote Resources
AlphaWire