Part # Type  Shielding  Voltage  AWG  # of Elements  Jacket Material  Jacket Diameter  Applicable Specifications 
1604 Conductor  UNSHIELDED  150  26  PVC  0.09  CA Prop 65 
(Ctrl+Click if PDF doesn't appear)
 Diameters (In)
1) Component 1 4 X 1 COND 
a) Conductor 26 (7/34) AWG BC 0.019
b) Insulation 0.009" Wall, Nom. Polypropylene(PP) 0.037
(1) Color(s)  
Cond Color Cond Color Cond Color
1 BLACK 3 GREEN 
2 RED 4 YELLOW 
2) Cable Assembly 4 Components run parallel under jacket. 
3) Jacket 0.020" Wall, Nom.,PVC0.090+/- 0.007
  X 0.190+/- 0.009
a) Color(s) SILVER
1) CE:EU Low Voltage Directive 2006/95/EC
1) CE: EU Directive 2011/65/EU(RoHS2), EU Directive 2015/863/EU (RoHS3):
 This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011 and the amending Directive 2015/863/EU of 4 June 2015 . No Exemptions are required for RoHS Compliance on this item. Consult Alpha Wire's web site for RoHS C of C.
2) REACH Regulation (EC 1907/2006):
 This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, please see Alpha's REACH SVHC Declaration.
3) California Proposition 65:Exempt from warning labels based on the Consent Judgment. Please see Alpha's CA Prop 65 Statement for more information.
Physical & Mechanical Properties
1) Temperature Range-20 to 60°C
2) Bend Radius 10X Cable Diameter
3) Pull Tension 8.7 Lbs, Maximum
Electrical Properties(For Engineering purposes only)
1) Voltage Rating 150 VRMS
2) Capacitance 13.3 pf/ft @1 kHz, Nominal Conductor to Conductor
3) Inductance0.2 µH/ft, Nominal
4) Conductor DCR38 Ω/1000ft @20°C, Nominal
PackagingFlange x Traverse x Barrel (inches)
a) BOX 1000FT 7-5/8 EASY REEL: Continuous length
b) BOX 328 FT 7-5/8 EASY REEL: Continuous length
 [Spool dimensions may vary slightly]

Communication and Control Cable:

Get Control Of Your Communication and Control Applications

Our line-up of standard communication and control cables gives you maximum choice and fewer tradeoffs. By offering you a comprehensive collection of insulation/jacketing materials, shielding options, and conductor counts, you can easily select the cable that meets your most demanding needs. We have cables that go beyond the ordinary to satisfy rigorous requirements of EMI performance, transmission distances, flexibility, and temperature extremes.

Communication and Control Typical applications:

  • Audio systems: speakers, microphones, intercoms

  • Broadcast and studio

  • Data transmission: RS-232, 422, 485

  • CAD/CAM

  • Computer peripherals

  • Business machines

  • Security systems: alarms, cameras, sensors

  • Control systems

  • Instrumentation systems

  • Point-of-sale systems

  • Banking systems

Low capacitance cables for improved transmission distances and signal integrity.