| JACKET
COLORS & COLOR CODES |
| |
Riser |
Plenum |
| JACKET
COLORS |
Blue,
White, Slate, Yellow |
Blue,
White, Slate, Yellow |
| |
Pair |
Tip |
Ring |
Tip |
Ring |
| Conductor
Color Code |
1 |
Blue |
White/Blue |
Blue |
White/Blue |
| |
2 |
Orange |
White/Orange |
Orange |
White/Orange |
| 3 |
Green |
White/Green |
Green |
White/Green |
| 4 |
Brown |
White/Brown |
Brown |
White/Brown |
|
|
| Alpha
Part No. |
Certifying
Agency Listings |
No.
of Pairs |
AWG
Stranding
Material*
DCR, Ohms/1000'
(Ohms/km), Max.
@ 20C |
Insulation
Material, Wall Thickness, Diameter,
Inches (mm) |
Nominal
Capacitance, pF/Ft. (pF/m)
@ 1 kHz |
Jacket
Material*, O.D., Nominal, Inches (mm) |
Frequency,
MHz |
Impedance,
Ohms |
PSACR,
dB/100M, Min. |
Attenuation,
dB/100M, Max. |
PSNEXT,
dB, Min. |
PSELFEXT,
dB/100M, Min. |
RL,
dB, Min. |
| 9604R |
NEC: CMR
UL-Type CMR
UL-1666 Flame Test
CEC: CMR FT-4
c(UL) Type CMR
CSA FT-4 Flame Test
ANSI TIA/EIA-568-B.2-1 Category 6
NEMA WC-66 Category 6 |
4 |
23
Solid Annealed BC
28.59 (93,8) |
Polyolefin
0.009 (0,23)
0.038 (0,97) |
15.00 (49,21) |
FR-PVC
0.235 (5,97) |
1
4
8
10
16
20
25
31.25
62.5
100
155
200
250 |
100 +/- 15%
100 +/- 15%
100 +/- 15%
100 +/- 15%
100 +/- 15%
100 +/- 15%
100 +/- 15%
100 +/- 15%
100 +/- 15%
100 +/- 15%
100 +/- 22%
100 +/- 32%
100 +/- 32% |
63.3
52.3
46.1
43.9
39.1
36.6
34.1
31.3
21.6
17.1
4.7
3.0
--- |
2.0
3.8
5.4
6.0
7.6
8.5
9.6
10.7
15.5
19.9
25.3
29.2
33.0 |
72.3
63.3
58.8
57.3
54.3
52.8
51.3
49.9
45.4
42.3
39.5
37.8
36.3 |
64.8
52.7
46.7
44.8
40.7
38.7
36.8
34.9
28.8
24.8
20.9
18.7
16.8 |
20.0
23.0
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1
18.8
18.0
17.3 |
| 9604F |
UL-Type
CMP
UL-910 Flame Test
NEC: CMP
c(UL) Type CMP
CEC: CMP FT-6
CSA FT-6 Flame Test
ANSI TIA/EIA-568-B.2-1 Category 6
NEMA WC-66 Category 6 |
4 |
23
Solid Annealed BC
28.59 (93,8) |
FEP
Teflon ®
0.008 (0,20)
0.035 (0,89) |
15.00
(49,21) |
FR-PVC
0.224 (5,69) |
1
4
8
10
16
20
25
31.25
62.5
100
155
200
250 |
100
+/- 15%
100 +/- 15%
100 +/- 15%
100 +/- 15%
100 +/- 15%
100 +/- 15%
100 +/- 15%
100 +/- 15%
100 +/- 15%
100 +/- 15%
100 +/- 22%
100 +/- 32%
100 +/- 32% |
63.3
52.3
46.1
43.9
39.1
36.6
34.1
31.3
21.6
17.1
4.7
3.0
--- |
2.0
3.8
5.4
6.0
7.6
8.5
9.6
10.7
15.5
19.9
25.3
29.2
33.0 |
72.3
63.3
58.8
57.3
54.3
52.8
51.3
49.9
45.4
42.3
39.5
37.8
36.3 |
64.8
52.7
46.7
44.8
40.7
38.7
36.8
34.9
28.8
24.8
20.9
18.7
16.8 |
20.0
23.0
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1
18.8
18.0
17.3 |
|
|
| PHYSICAL
CHARACTERISTICS |
| |
Riser |
Plenum |
| > Temperature
Range, C |
-20°C
to +75°C |
-20°C
to +75°C |
| > Pulling
Tension, Lbs, Max. |
40 Lbs.
(18 kg) |
40
Lbs. (18 kg) |
| > Bending
Radius, Inches (mm), Min. |
0.50 Inches
(1,3 cm) |
0.50
Inches (1,3 cm) |
|
| ELECTRICAL
CHARACTERISTICS |
| |
Riser |
Plenum |
| > DCR, Ohms/1000
Ft(Ohms/km) @ 20C, Nom |
28.59 (93,8) |
28.59 (93,8) |
| > DC Unbalance,
%, Max. |
5 |
5 |
| > Impedance, Ohms,
Nom |
100 (100) |
100 (100) |
| > Velocity of Propagation,
%, Nom. |
70 (70) |
72 (72) |
| > Capacitance Unbalance,
pF/100 meters |
330 |
330 |
| > Capacitance,
pF1000 Ft(pF/m @ 1 kHz, Nom. |
15.00 (49,21) |
15.00 (49,21) |
| > Operating Voltage,
Vrms, Max. |
300 (300) |
300 (300) |
| > Delay Skew, nsec/100
meters, max. |
45 |
45 |
| > Delay @ 100 MHz,
nsec/100 meters, max. |
537 |
537 |
|
| AGENCY
COMPLIANCE |
| |
Riser |
Plenum |
| > Underwriters
Laboratories (UL) |
Type
CMR |
Type
CMP |
| > Underwriters
Laboratories (UL) - Flame Test |
UL
1666 Vertical Shaft |
UL
910 Steiner Tunnel |
| > Canadian
Standards Assoc. [c(UL)] |
Type
CMR |
Type
CMP |
| > Canadian
Standards Assoc. [c(UL)] - Flame Test |
CSA
FT-4 |
CSA
FT-6 |
| > ANSI/TIA/EIA
568-B.2-1 |
Category
6 |
Category
6 |
| > NEMA
WC 63.1 |
Category
6 |
Category
6 |
|
|
| Notes: |
1.
Zo & RL values are based upon swept frequency cable input measurements
only. |
|
2.
Curve fitting functions have not been applied to improve values. |
|
3.
RL values based upon 100-ohm impedance. |
|
4.
Table data based upon discrete measurements; All cables tested to
250 MHz. |
| FEATURES & BENEFITS |
| > Engineered
for end-users who demand high bandwidth coupled with high
performance. |
| > Provides
increased reliability & network optimization. |
| > All
cables tested & characterized to 250 MHz. |
| > Rip
Cords included with both Plenum & Non-Plenum designs to
facilitate jacket removal. |
| > Sequential
footage markers at 2 ft. intervals to aid in installations. |
| > Third
party verified to TIA/EIA 568-B.2 for guaranteed performance. |
| > Rod
filler to maintain core geometry. |
| > Ideal
for use in high bandwidth applications such as Gigabit Ethernet & 622
ATM. |
| |
| APPLICATIONS |
| > 100
Base TX & 10 Base-T |
| > 100
Base VG Anylan |
| > ATM
- 155 Mp/sec |
| > Gigabit
Ethernet - IEEE 802.3 1000BASE-T |
| > ATM
- 622 Mp/sec |
| > 4/16
Mb/sec Token Ring |
| > Broad- & Base-band
Analog Video |
|
|