Wire, Cable and Tubing Solutions from Alpha Wire Company
   








  

FIBER OPTICS

TACTICAL CABLE


Choose Tactical Cables For:

  • ENG Vehicles
  • Outdoor News and Sporting Events
  • Re-deployable Communications
  • Digital Camera Transmission

Characteristics:

OPERATING TEMPERATURE:

  • -70° to 85°C (Storage)
  • -55° to 85°C (Operating)

COLOR DESCRIPTION:

  • Tight Buffer: EIA/TIA 598-A
  • Jacket: Black

PRODUCT DESCRIPTION:

  • Tight Buffer: Thermoplastic
  • Strength Member: Aramid Yarn
  • Jacket: UV Resistant Polyurethane

Availability:

  • Bulk, Cut To Length (Minimums May Apply)

Side view of the Fiber Optic Cable described

Cross Section Diagram of the Fiber Optic Cable described

Specifications:

  • Crush Resistance (EIA-455-41): 440N/cm
  • Impact Resistance (EIA-455-25):
    200 Impacts @2.2 N-m
  • Cyclic Flexing (EIA-455-104): 2000 Cycles, min.
  • Min. Ben Radius, Installation: 15X Cable O.D.
  • Min. Ben Radius, Long Term: 8X Cable O.D.
  • See Page 1 for Optical Specifications

  ALPHA PART NUMBER  
Fiber
Count
62.5/125mm
Std./1 Gbe
Single-Mode
Enhanced
Outside Diameter Weight Max. Install Load
Inches mm Lbs./M' kg/km Lbs. Newtons
2 M96571 M96566 0.217 5,5 19 28 330 1468
4 M96551 M96639 0.225 5,7 21 31 330 1468
6 M96572 M96567 0.236 6,0 23 34 330 1468
8 M96573 M96568 0.250 6,3 26 39 330 1468
10 M96574 M96569 0.265 6,7 28 42 330 1468
12 M96575 M96570 0.280 7,1 31 46 330 1468
50/125mm Fiber also available.


Email: info@alphawire.com
Toll Free: 1-800-52 ALPHA | Telephone: 908-925-8000 | Fax: 908-925-6923
Europe/UK Telephone: +44 (0) 800 288 8809 | Europe/UK Fax: +44 (0) 1932 772433