| 1.0 |
PRODUCT
SPECIFICATIONS |
| 1.1 |
Finely stranded
tinned copper conductor per ASTM
B-3 |
| 1.2 |
Power conductor
size range 24 AWG thru 8 AWG |
| 1.3 |
Data conductor size
range 18 AWG thru 16 AWG |
| 1.4 |
Premium lubricated
polyvinylchloride or Thermoplastic Elastomer
insulated conductors |
| 1.5 |
Black conductors numbered white with an unnumbered green/yellow grounding conductor |
| 1.6 |
UL, CSA conductor
styles --- 600 volts
UL Style 1015, 10162
CSA AWM I A/B 90°C |
| 1.7 |
UL, CSA cable styles
--- 600 volts
UL Style 20626
CSA AWM I A/B II A/B FT1 |
| 1.8 |
Shielding
A) Power Cable:
Overall aluminum/polyester, tinned copper
Drain Wire,
85% tinned copper braid
B) Composite Cable:
Individual shielded pairs, aluminum/polyester,
tinned copper drain wire,
85% tinned copper braid. Part Number S61224CY
has one single
shielded double pair, pairs are not individually
shielded.
Overall shield of aluminum/polyester, tinned
copper Drain Wire, 85% tinned copper braid. |
| 1.9 |
Jacketing
A) Oil resistant Thermoplastic Elastomer
B) Available in orange |
| 2.0 |
PERFORMANCE |
| 2.1 |
Power Supply Cable
for Connecting Servo System Motors to Drives,
Controllers and Power Supplies (Servo) |
| 2.2 |
Power Supply and
Data Cable for Connecting Servo System Motors and Electro-mechanical
Devices to Drives, Controllers and Power Supplies (Composite) |
| 2.3 |
For Temperature
Feedback and Braking Control, Two Individually Shielded
Pairs are
Added to the 3 Power and One Ground Conductor (Composite) |
| 2.4 |
UL Recognized and
CSA Certified, CE Marked |
| 3.0 |
APPLICATIONS |
| 3.1 |
Machine Tools |
| 3.2 |
Automated Pick and
Place Systems |
| 3.3 |
"C Track" or Stationary
Applications |
| 3.4 |
Automated
Handling Systems |
| 4.0 |
JACKET
TEST DATA |
| 4.1 |
|
| 4.2 |
Flame Retardancy
UL VW-1
CSA FT1 |