Wire, Cable and Tubing Solutions from Alpha Wire Company
   








  
TECHNICAL DATA
INSULATION AND JACKETING MATERIALS PROPERTIES




INSULATION MATERIALS PROPERTIES CHART
PROPERTIES TEFZEL ETFE NATURAL RUBBER HYPALON NEOPRENE SILICONE POLYURETHANE
1 Abrasion Resistance Good Excellent Good Excellent Fair Excellent
2 Heat Resistance Excellent Fair Excellent Good Excellent Good
3 Weatherability Good Fair Excellent Good Excellent Good
4 Flame Retardancy Excellent Poor Good Good Good Good
5 Water Resistance Excellent Good Good Excellent Excellent Good
6 Acid Resistance Excellent Fair Excellent Good Good Fair
7 Alkali Resistance Excellent Fair Excellent Good Good Fair
8 Aliphatic Hydro. Resis. Excellent Poor Fair Good Poor Good
9 Aromatic Hydro. Resis. Excellent Poor Fair Fair Poor Poor

PROPERTIES ASTM
METHOD
TEFZEL
ETFE
NATURAL
RUBBER
HYPALON NEOPRENE SILICONE POLY-
URETHANE
1 Specific Gravity D-792-66 1.70-1.86 1.3-1.7 1.35-1.7 1.23-1.65 1.1-1.6 1.30
2 Tensile Strength, psi D-638-77 6500 1500-4000 1200-2200 1200-2700 1000 >3500
3 Elongation, % D-412-75 200 300-700 300-600 300-700 100-500 540-750
4 Volume Resistivity ,
    ohm-cm
D-257-78 >1016 1013-1016 1012-1014 1011-1013 2 x 1014
8 x 1013
11 x 1014
5 Dielectric Strength,
    volts/mil
D-149-75 500 --- 500 600 100-700 330-630
6 Dielectric Constant
    @ 60 Hz
D-150-78 2.6 --- --- --- --- 5.4-7.6
7 Dielectric Constant
    @ 1 kHz
D-150-78 2.6 2.3-3.0 9.0-11.0 5.0-7.0 3.0-3.5 5.6-7.6
8 Power Factor
    (Dissipation) @ 60 Hz
D-150-78 --- --- --- --- --- 0.015-0.046
9 Power Factor
    (Dissipation) @ 1 kHz
D-150-78 0.0006 .00023-
.00030
0.05-0.07 3.5 0.001-0.010 0.043-0.060

The above chart reflects a qualitative comparison of insulating properties and should be used as a general guide only.
For specific compound information, consult Alpha's Engineering Staff.
Note:  All values shown are nominal.

XTRA•GUARD® CHEMICAL RESISTANCE CHART
 
Kerosene
JP-4
JP-5
Alcohols
MEK
Hydrochloric
Acid
(10%)
Sulfuric
Acid
(10%)
Acetone
Carbon
Tetrachloride
TriChlor
ethylene
Chlorine
(Wet)
XTRA•GUARD® 1
P
P
P
G
P
E
G
P
F
P
G
XTRA•GUARD® 2
F
P
P
F
P
F
F
P
P
P
P
XTRA•GUARD® 3
G
P
P
G
P
G
G
P
F
P
P
XTRA•GUARD® 4
F
P
P
G
P
G
G
P
F
P
P
XTRA•GUARD® 5
E
E
E
E
E
E
E
E
E
E
E

This chart is to be used as a general reference guide only, for casual exposure at room temperature.  These recommendations are based upon test results believed reliable.  Alpha Wire does not guarantee the results to be obtainable in all instances.
E = Excellent G = Good
F = Fair P = Poor
 
Email: info@alphawire.com
Toll Free: 1-800-52 ALPHA | Telephone: 908-925-8000 | Fax: 908-925-6923
Europe/UK Telephone: +44 (0) 800 288 8809 | Europe/UK Fax: +44 (0) 1932 772433
 
 

Master Catalog Page
Previous
357
Previous

Alpha Wire Company

Copyright © 2008 Alpha Wire Company ALL RIGHTS RESERVED.

Use of this Web Site indicates you accept the Terms of Use
listed in the Legal Information and Terms Of Use Document.