CHOOSE
TINNED
COPPER BRAID FOR: |
- Ground/Shielding
Terminations
|
TINNED
COPPER BRAID
APPLICATIONS: |
- Point-to-Point Ground Path
- Wire/Cable Shielding
|
|
CHARACTERISTICS |
|
Product Description: |
- Flat or Oval Shaped Tinned
Copper Braid
|
| SPECIFICATIONS: |
- QQ-W-343E
- ASTM-B-33
- + Meets QQ-B-575B
- RoHS Compliant
|
|
|
|
|
SHIELDING, GROUND STRAP:
A tight weave of multi-strand, soft drawn
tinned copper wire; tinned copper braid is an
ideal shielding material for short-run cables pro-
viding easy radial termination. In retrofit appli-
cations, provides additional shielding
efficiency. Tinned copper flat braid, used
as a Ground strap, provides an excellent, low-
resistance Ground path.
| TINNED
COPPER FLAT BRAID |
|
|
Nom.
Flat Width
|
Nom.
Thickness
|
Braid
Construction
|
|
|
|
|
|
Alpha
Part No.
|
Inches
|
mm
|
Inches
|
mm
|
AWG
of Indiv. Ends
|
Carriers
|
Total
No. of Indiv. Ends
|
Approx.
AWG Equiv.
|
|
Approx.Current
Carrying Cap. (amps)^
|
Standard
Package Spools Ft.
|
|
|
.025
1/32
3/64
3/32
1/8
3/16
1/4
3/8
5/8
1/2
3/4
1
1-3/8
1-1/2
1-3/4
2
3
|
0,63
0,79
1,19
2,38
3,18
4,76
6,35
9,53
15,90
12,70
19,10
25,40
34,90
38,10
44,50
50,80
76,20
|
0.015
0.020
0.020
0.020
0.020
0.020
0.030
0.030
0.030
0.030
0.040
0.045
0.050
0.060
0.080
0.120
0.200
|
0,38
0,50
0,50
0,50
0,50
0,50
0,76
0,76
0,76
0,76
1,02
1,14
1,27
1,52
2,03
3,05
5,08
|
36
36
36
36
36
36
36
36
36
36
36
36
30
30
30
30
30
|
8
16
24
16
24
24
24
48
48
48
48
48
48
48
48
48
48
|
8
16
24
48
72
120
168
288
384
384
864
864
336
528
1248
1436
2256
|
27
24
22
19
18
15
14
12
10
10
7
7
5
3
2/0
3/0
4/0
|
200
400
600
1200
1800
3000
4200
7200
9600
9600
20800
20800
33700
53064
125424
154368
225000
|
4
6
7
11
16
25
32
46
53
53
85
85
100
150
280
310
390
|
100, 500, 1000
100, 500, 1000
100, 500, 1000
100, 500, 1000
100, 500, 1000
100, 500, 1000
100, 500, 1000
100, 500, 1000
100, 500, 1000
100, 500, 1000
100, 500, 1000
100, 500, 1000
100, 500, 1000
100
100
100
100
|
|
|
|
TINNED
COPPER OVAL BRAID
|
|
Nom. I.D. When Rounded
|
Braid
Construction
|
|
|
|
|
|
Alpha
Part No.
|
Inches
|
mm
|
AWG
of Indiv. Ends
|
Carriers
|
Total
No. of Indiv. Ends
|
Approx.
AWG Equiv.
|
|
Approx.Current
Carrying Cap. (amps)^
|
Standard
Package Spools Ft.
|
|
|
1/16
11/64
3/16
1/4
3/8
1/2
5/8
11/16
25/32
|
1,59
4,37
4,76
6,35
9,53
12,70
15,88
17,46
19,84
|
34
34
34
34
34
34
34
34
34
|
16
24
24
24
24
48
48
48
48
|
32
120
144
168
192
336
384
480
528
|
|
1192
4770
5724
6678
7632
13356
14264
19080
20988
|
11
32
38
41
46
62
64
81
85
|
100, 500, 1000
100, 500, 1000
100, 500
100, 500
100, 500
100
100
100
100
|
|
|
*Values shown are for bare cable in free air
at 30° C (86° F) and intended as a reference guide only.
Actual values will depend on permissible temperature rise, permissible voltage
drop and other