# de pieza Type  Shielding  Voltage  AWG  # of Elements  Jacket Diameter  Applicable Specifications 
45010/20 Conductor  UNSHIELDED  300  22  20  0.441  CA Prop 65, CE, CSA AWM I/II A/B, CSA FT1, Pennsylvania Bureau of Mine Safety Approved, UL AWM 20237, UL PLTC 
(Ctrl+Click if PDF doesn't appear)
 Diameters (In)
1) Component 1 20 X 1 COND 
a) Conductor 22 (7/30) AWG Tinned Copper 0.030
b) Insulation 0.016" Wall, Nom. TPE 0.062
(1) Color Code Alpha Wire Color Code E
Cond Color Cond Color Cond Color
1 BLACK 8 VIOLET15 WHITE/YELLOW
2 BROWN 9 SLATE16 WHITE/GREEN
3 RED 10 WHITE17 WHITE/BLUE
4 ORANGE 11 WHITE/BLACK18 WHITE/VIOLET
5 YELLOW 12 WHITE/BROWN19 WHITE/SLATE
6 GREEN 13 WHITE/RED20 WHITE/BLACK/BROWN
7 BLUE 14 WHITE/ORANGE 
2) Cable Assembly 20 Components Cabled 
a) Twists: 3.2 Twists/foot (min) 
b) Core Wrap Nonwoven Polyester Tape, 25% Overlap, Min. 
3) Jacket 0.055" Wall, Nom.,TPE0.441 (0.462 Max.)
a) Color(s) Slate, Black, Yellow, Orange, Blue, Green, Red, Sand Beige, White
b) Ripcord 1 End 810 Denier Nylon 
c) Print ALPHA WIRE-* P/N 45010/20 20C 22 AWG
XTRAGUARD(R) 4 (UL) TYPE PLTC 105C SUN RES OR AWM
21916 125C 300 V OR CRU AWM I/II A/B 125C 300V
FT1 P-07-KA140023-MSHA
CE ROHS (SEQ FOOTAGE)
* = Factory Code
1) UL AWM/STYLE 21916 125°C / 300 VRMS
 PLTC 105°C
 SUN RES 
2) CSA International C(RU) AWM I/II A/B FT1 125°C / 300 VRMS
 SUN RES (Black only) 
3) Other PENNSYLVANIA BUREAU OF MINE SAFETY APPROVED 
4) CE:EU Low Voltage Directive 2006/95/EC
1) CE: EU Directive 2011/65/EU(RoHS2):
 This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011. No Exemptions are required for RoHS Compliance on this item. Consult Alpha Wire's web site for RoHS C of C.
2) California Proposition 65:The outer surface materials used in the manufacture of this part meet the requirements of California Proposition 65.
Physical & Mechanical Properties
1) Temperature Range-50 to 125°C
2) Bend Radius 10X Cable Diameter
3) Pull Tension 110 Lbs, Maximum
4) Sunlight Resistance Yes
Electrical Properties(For Engineering purposes only)
1) Voltage Rating 300 VRMS
2) Capacitance 14.3 pf/ft @1 kHz, Nominal Conductor to Conductor
3) Inductance0.2 µH/ft, Nominal
4) Conductor DCR16.6 Ω/1000ft @20°C, Nominal
PackagingFlange x Traverse x Barrel (inches)
a) 1000 FT 24 x 14 x 12 Continuous length
b) 500 FT 18 x 12 x 8 Continuous length
c) Bulk(Made-to-order) 
 [Spool dimensions may vary slightly]
Notes:
a) Print legend will contain CSA SUN RES on black cables only.

Xtra-Guard® 4 - Apto para temperaturas extremas, tolera calor y frío High TemperatureLow TemperatureUltraviolet LightEMI Noise

    • Cable de temperatura extendida con un rango de temperatura que oscila entre -50 ºC y +125 ºC
    • Presenta aislamiento TPE de alto rendimiento y una cubierta exterior que triplican la flexibilidad a baja temperatura del PVC común
    • Resistencia moderada a aceites, solventes, sustancias químicas y combustibles
    • Excepcional estabilidad a la luz ultravioleta en todos los colores de cubierta exterior 
    • Calificación UL: 600 V TC y 300 V PLTC para aplicaciones de bandejas de cables (excepto 24 AWG)
    • Aprobado por la Pennsylvania Bureau Deep Mining Safety (Oficina de Seguridad en Minas Profundas de Pensilvania) para sistemas de control que abarcan toda la mina
    • Brinda protección excepcional contra la interferencia electromagnética cuando se especifica Supra-Shield

Solicite una muestra Descargar el catálogo Consultar a un experto

¿Necesita un diseño más personalizado?

Solicite un presupuesto personalizado Recursos
AlphaWire