# de pieza Type  Shielding  Voltage  AWG  # of Elements  Jacket Diameter  Applicable Specifications 
35058 Conductor  UNSHIELDED  300  20  0.3  CA Prop 65 
(Ctrl+Click if PDF doesn't appear)
 Diameters (In)
1) Component 1 8 X 1 COND 
a) Conductor 20 (7/28) AWG TC 0.038
b) Insulation 0.016" Wall, Nom. PVC 0.070
(1) Color Code Alpha Wire Color Code D
Cond Color Cond Color Cond Color
1 BLACK 4 GREEN7 BROWN
2 RED 5 ORANGE8 YELLOW
3 WHITE 6 BLUE 
2) Cable Assembly 8 Components Cabled 
a) Twists: 3.4 Twists/foot (min) 
b) Core Wrap Clear Mylar Tape, 25% Overlap, Min. 
3) Jacket 0.032" Wall, Nom.,Polyethylene (PE)0.300 (0.314 Max.)
a) Color(s) Slate, Black, Yellow, Orange, Blue, Green, Red, Sand Beige, White
b) Ripcord 1 End 810 Denier Nylon 
c) Print ALPHA WIRE-* P/N 35058 8C 20 AWG
XTRAGUARD(R) 3 80C 300 VOLTS CE ROHS
(SEQ FOOTAGE)
* = Factory Code
1) CE:EU Low Voltage Directive 2006/95/EC
1) CE: EU Directive 2011/65/EU(RoHS2):
 This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011. No Exemptions are required for RoHS Compliance on this item. Consult Alpha Wire's web site for RoHS C of C.
2) REACH Regulation (EC 1907/2006):
 This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, please see Alpha's REACH SVHC Declaration.
3) California Proposition 65:The outer surface materials used in the manufacture of this part meet the requirements of California Proposition 65.
Physical & Mechanical Properties
1) Temperature Range-30 to 80°C
2) Bend Radius 10X Cable Diameter
3) Pull Tension 70 Lbs, Maximum
4) Sunlight Resistance Yes
5) Direct Burial Yes
Electrical Properties(For Engineering purposes only)
1) Voltage Rating 300 VRMS
2) Capacitance 30 pf/ft @1 kHz, Nominal Conductor to Conductor
3) Inductance0.19 µH/ft, Nominal
4) Conductor DCR10.2 Ω/1000ft @20°C, Nominal
PackagingFlange x Traverse x Barrel (inches)
a) 1000 FT 16 x 11 x 8 Continuous length
b) 500 FT 12 x 10 x 5 Continuous length
c) Bulk(Made-to-order) 
 [Spool dimensions may vary slightly]

Xtra-Guard® 3 - Tendido subterráneo directo-no requiere conducto Ultraviolet LightOil, Chemicals, Solvents, FuelsDirect BurialEMI Noise

    • El cable de exteriores preferido para el tendido subterráneo directo 
    • Seis veces la resistencia hídrica del PVC 
    • Presenta una cubierta exterior de polietileno especialmente formulada de excelente vida útil y estabilidad a la luz ultravioleta en todos los colores de cubierta exterior 
    • Resistente a los efectos de la intemperie, la humedad y el envejecimiento por rayos UV sin el uso costoso de tuberías 
    • Supra-Shield® brinda excepcional protección contra el ruido conductivo o eléctrico en ambientes de alta y baja frecuencia donde la interferencia electromagnética es penetrante

Solicite una muestra Descargar el catálogo Consultar a un experto

¿Necesita un diseño más personalizado?

Solicite un presupuesto personalizado Recursos
AlphaWire