# de pieza Type  Shielding  Voltage  AWG  # of Elements  Jacket Diameter  Applicable Specifications 
25010/20 Conductor  UNSHIELDED  300  22  20  0.331  CA Prop 65, CE, CSA AWM I/II A/B, CSA FT1, UL AWM 10002, UL AWM 20668, UL VW-1 
(Ctrl+Click if PDF doesn't appear)
 Diameters (In)
1) Component 1 20 X 1 COND 
a) Conductor 22 (7/30) AWG TC 0.030
b) Insulation 0.010" Wall, Nom. PVC, Semi Rigid 0.050
(1) Color Code Alpha Wire Color Code E
Cond Color Cond Color Cond Color
1 BLACK 8 VIOLET15 WHITE/YELLOW
2 BROWN 9 SLATE16 WHITE/GREEN
3 RED 10 WHITE17 WHITE/BLUE
4 ORANGE 11 WHITE/BLACK18 WHITE/VIOLET
5 YELLOW 12 WHITE/BROWN19 WHITE/SLATE
6 GREEN 13 WHITE/RED20 WHITE/BLACK/BROWN
7 BLUE 14 WHITE/ORANGE 
2) Cable Assembly 20 Components Cabled 
a) Twists: 4.0 Twists/foot (min) 
b) Core Wrap Nonwoven Polyester Tape, 25% Overlap, Min. 
3) Jacket 0.032" Wall, Nom.,Polyurethane (TPU)0.331 (0.349 Max.)
a) Color(s) Slate, Black, Yellow, Orange, Blue, Green, Red, Sand Beige, White
b) Ripcord 1 End 810 Denier Nylon 
c) Print ALPHA WIRE-* P/N 25010/20
XTRAGUARD(R) 2 RU AWM 20668 VW-1 --- LLXXXXXX CSA
AWM I/II A/B 90C 300 VOLTS FT1 CE
ROHS (SEQ FOOTAGE)
* = Factory Code
[Note: Product may have c(UL) or CSA markings depending upon plant of manufacture.]
1) UL   
a) Component 1 AWM/STYLE 10002 105°C / 300 VRMS
b) Overall AWM/STYLE 20668 90°C / 300 VRMS
 VW-1 
2) CSA International AWM I/II A/B 90°C / 300 VRMS
 FT1 
3) CE:EU Low Voltage Directive 2006/95/EC
1) CE: EU Directive 2011/65/EU(RoHS2):
 This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011. No Exemptions are required for RoHS Compliance on this item. Consult Alpha Wire's web site for RoHS C of C.
2) REACH Regulation (EC 1907/2006):
 This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, please see Alpha's REACH SVHC Declaration.
3) California Proposition 65:The outer surface materials used in the manufacture of this part meet the requirements of California Proposition 65.
Physical & Mechanical Properties
1) Temperature Range-30 to 90°C
2) Bend Radius 10X Cable Diameter
3) Pull Tension 110 Lbs, Maximum
4) Sunlight Resistance Yes
Electrical Properties(For Engineering purposes only)
1) Voltage Rating 300 VRMS
2) Capacitance 23.5 pf/ft @1 kHz, Nominal Conductor to Conductor
3) Inductance0.18 µH/ft, Nominal
4) Conductor DCR16.6 Ω/1000ft @20°C, Nominal
PackagingFlange x Traverse x Barrel (inches)
a) Bulk(Made-to-order) 

Xtra-Guard® 2 - Resistente a la abrasión para soportar el abuso mecánico  Ultraviolet Light Oil, Chemicals, Solvents, Fuels Abrasion EMI Noise

    • Cable resistente para usar en aplicaciones industriales en las que la abrasión y el abuso mecánico son comunes
    • Presenta una cubierta exterior de poliuretano resistente especialmente formulada que triplica la resistencia al desgaste y a la abrasión del PVC común
    • Brinda resistencia extrema a los cortes y al daño físico
    • Diseñado con resistencia moderada a alta a la mayoría de los aceites, solventes, sustancias químicas y combustibles
    • Ofrece una excelente estabilidad a la luz ultravioleta en todos los colores de cubierta exterior
    • Brinda protección excepcional contra la interferencia electromagnética cuando se especifica Supra-Shield


Solicite una muestra Descargar el catálogo Consultar a un experto

¿Necesita un diseño más personalizado?

Solicite un presupuesto personalizado Recursos
AlphaWire