(Ctrl+Click if PDF doesn't appear)
Construction
| Diameters (In) |
1) Component 1 | 3 X 1 COND | |
a) Conductor | 10 (105/30) AWG Bare Copper | 0.118 |
b) Insulation | 0.022" Wall, Nom. PVC/ 0.005" Wall NYLON | 0.172 |
(1) Print | ALPHANUMERIC NUMBERS - 1-ONE ALTERNATING AND INVERTED
|
(2) Color Code | Alpha Wire Color Code RX |
Cond | Color | Cond | Color | Cond | Color | 1 | GREEN/YELLOW | 2 | RED#1 | 3 | RED#2 |
|
2) Cable Assembly | 3 Components Cabled | |
a) Twists: | 3.4 Twists/foot (min) | |
b) Orientation: | Components to be arranged from OUTSIDE LAYER to INSIDE LAYER | |
c) Core Wrap | REMAY Tape, 25% Overlap, Min. | |
3) Jacket | 0.050" Wall, Nom.,PVC | 0.487+/- 0.024 |
a) Color(s) | BLACK |
b) Print | ALPHA WIRE-* P/N XM1003R 3C 10 AWG (5.32mm2) THWN-2 SERIES XM (UL) WTTC 90C WET/DRY 1000V OR (UL) TC-ER 90C WET/DRY 600V SUN RES DIR BUR OIL RES I OR MTW 10 AWG OR CRU AWM I/II A/B 90C 600V FT4 CE ROHS (DATE CODE) (SEQ FOOTAGE) * = Factory Code
|
Applicable Specifications
1) UL | | |
a) Component 1 | THWN-2 | 90°C Dry / 90°C Wet / 600 VRMS |
b) Overall | MTW | 90°C Dry / 60°C Wet / 600 VRMS |
| TC | 90°C Dry / 90°C Wet / 600 VRMS |
| EXPOSED RUN | |
| SUN RES | |
| OIL RES I | |
| WTTC | 90°C Dry / 90°C Wet / 1000 VRMS |
2) CSA International | C(RU) AWM I/II A/B | 90°C / 600 VRMS |
| FT4 | |
3) Other | Conductors ASTM Class K | |
| Conductors IEC Class 5 on AWG size | |
4) CE: | EU Low Voltage Directive 2014/35/EC |
Environmental
1) CE: EU Directive 2011/65/EU(RoHS2): |
| This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011and the amending Directive 2015/863/EU of 4 June 2015 . No Exemptions are required for RoHS Compliance on this item. Consult Alpha Wire's web site for RoHS C of C. |
2) REACH Regulation (EC 1907/2006): |
| This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, please see Alpha's REACH SVHC Declaration. |
3) California Proposition 65: | Exempt from warning labels based on the Consent Judgment. Please see Alpha's CA Prop 65 Statement for more information. |
Properties
Physical & Mechanical Properties |
---|
1) Temperature Range | -30 to 90°C(static), -5 to 90°C (dynamic) |
2) Bend Radius | 6X Cable Diameter(static), 8X Cable Diameter(dynamic) |
3) Pull Tension | 247 Lbs, Maximum |
4) Sunlight Resistance | Yes |
Electrical Properties | (For Engineering purposes only) |
---|
1) Voltage Rating | 600/1000 VRMS |
2) Capacitance | 37 pF/ft @1 kHz, Nominal Conductor to Conductor
|
3) Inductance | 0.16 µH/ft, Nominal
|
4) Conductor DCR | 1.03 Ω/1000ft @20°C, Nominal
|
Other
Packaging | Flange x Traverse x Barrel (inches) |
a) Bulk(Made-to-order) | |
Notes: |
a) Suitable for constant flexing where cycle count will be less than 12,000,000 cycles. |
Industrial Series XM (Flex Control):
Series XM Flex Control Cable is the ideal choice for medium-to-high-flex applications. Featuring a premium-grade PVC jacket, Series XM offers a durable, oil-resistant construction that prevents contamination from hazardous fluids and protects against abrasion. Plus, its optimum flexibility and performance allows it to support a variety of industrial applications, including:
- High-speed pick-and-place robotic systems
- Automated material handling equipment
- Conveyors and transfer shuttles
- Flex track installations
Series XM Product Breakdown:
- Meets NFPA Standard 79 for industrial machinery
- Stranded conductors for better flexibility
- Specially formulated PVC jacket and insulation for continuous flex applications and resistance to moisture, oils, coolants, and UV radiation
- Up to 65 conductors
- 8 to 18 AWG wire range
- Shielded or unshielded
- Black, blue, or red insulation for AC and DC circuits
- Rated for up to 12 million flex life cycles