Part # Voltage  # of Elements  AWG  Stranding  Insulation Thickness  Insulation Diameter  Insulation Material  Applicable Specifications 
3532 150/600  20  22  19/34  0.01  1.04 x .052  PVC  MIL-W-16878/1 Type B, UL AWM 2713, UL VW-1 
(Ctrl+Click if PDF doesn't appear)
 Diameters (In)
1) Component 1 20 X 1 COND 
a) Conductor 22 (19/34) AWG TC 0.032
b) Insulation 0.010" Wall, Nom. PVC 0.052
(1) Color(s)  
Cond Color Cond Color Cond Color
1 BROWN 8 SLATE15 GREEN
2 RED 9 WHITE16 BLUE
3 ORANGE 10 BLACK17 VIOLET
4 YELLOW 11 BROWN18 SLATE
5 GREEN 12 RED19 WHITE
6 BLUE 13 ORANGE20 BLACK
7 VILOET 14 YELLOW 
2) Cable Assembly 20 Components assembled parallel.0.052 +/- 0.002 x
  1.040 +/- 0.040
1) UL AWM/STYLE 2713 80°C / 150 VRMS
 VW-1 
2) Military   
a) Component 1 MIL-DTL-16878/1 (Type B) 105°C / 600 VRMS
1) EU Directive 2011/65/EU(RoHS2):
 All materials used in the manufacture of this part are in compliance with European Directive 2011/65/EU regarding the restriction of use of certain hazardous substances in electrical and electronic equipment. Consult Alpha Wire's web site for RoHS C of C.
2) REACH Regulation (EC 1907/2006):
 This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, please see Alpha's REACH SVHC Declaration.
3) California Proposition 65:The outer surface materials used in the manufacture of this part meet the requirements of California Proposition 65.
Physical & Mechanical Properties
1) Temperature Range-55 to 105°C
2) Bend Radius 10X Cable Diameter
3) Pull Tension 118 Lbs, Maximum
Electrical Properties(For Engineering purposes only)
1) Voltage Rating 600 VRMS
2) Capacitance 34 pf/ft @1 kHz, Nominal Conductor to Conductor
3) Inductance0.17 µH/ft, Nominal
4) Conductor DCR15.1 Ω/1000ft @20°C, Nominal
PackagingFlange x Traverse x Barrel (inches)
a) 100 FT 11 x 1.5 x 3 Continuous length
 [Spool dimensions may vary slightly]