Part # Material  ID  Wall Thickness  Temperature  Colors  Ratings 
FNT-1/2 PVC  0.622    -18 to 50  Black  CSA C22.2 No. 227.3-05, UL 1696 
(Ctrl+Click if PDF doesn't appear)
1) Tubing Type Electrical Tubing
2) Tubing Material Flexible Liquid Tight PVC Tubing
3) Minimum ID (In) 0.622
4) Maximum ID (In) 0.642
5) Minimum OD (In) 0.820
6) Maximum OD (In) 0.840
7) Color(s) BLACK
1) UL STANDARD 1696 50°C
2) CSA International C22.2 No. 227.3-05 (except 1/4) 50°C
1) EU Directive 2011/65/EU(RoHS2):
 All materials used in the manufacture of this part are in compliance with European Directive 2011/65/EU regarding the restriction of use of certain hazardous substances in electrical and electronic equipment. Consult Alpha Wire's web site for RoHS C of C.
2) California Proposition 65:The outer surface materials used in the manufacture of this part meet the requirements of California Proposition 65.
Physical & Mechanical Properties
1) Temperature Range -18 to 50°C 
Electrical Properties
Chemical Properties
1) Corrosion(0°C,16hrs) no corrosion AMS-DTL-23053
2) Fungus Resistance Pass AMS-DTL-23053
3) Halogen Free No 
4) Lead Free Yes 
Packaging
100 FT, 25 FT

Offering protection from flammability, high heat, abrasion, and chemicals.  Alpha tubing has the size for your wire and cable routing needs.

Request a Sample Download Brochure Consult a Cable Expert

Need a more unique construction? Different color code? Different color Jacket?

Request a Custom Quote Resources