Part # Type  Shielding  Voltage  AWG  # of Elements  Jacket Diameter  Applicable Specifications 
45470/40 Conductor  FOIL  300  20  40  0.65  CA Prop 65, CE, CSA AWM I/II A/B, CSA FT1, Pennsylvania Bureau of Mine Safety Approved, UL AWM 20237, UL PLTC 
(Ctrl+Click if PDF doesn't appear)
 Diameters (In)
1) Component 1 40 X 1 COND 
a) Conductor 20 (7/28) AWG Tinned Copper 0.038
b) Insulation 0.016" Wall, Nom. TPE 0.070
(1) Color Code Alpha Wire Color Code D
Cond Color Cond Color Cond Color
1 BLACK 15 RED/BLACK29 WHITE/BLACK/BROWN
2 RED 16 WHITE/BLACK30 WHITE/BLACK/ORANGE
3 WHITE 17 WHITE/RED31 WHITE/BLACK/SLATE
4 GREEN 18 WHITE/GREEN32 WHITE/BLACK/VIOLET
5 ORANGE 19 WHITE/YELLOW33 WHITE/BLACK/BLACK
6 BLUE 20 WHITE/BLUE34 WHITE/RED/BLACK
7 BROWN 21 WHITE/BROWN35 WHITE/RED/RED
8 YELLOW 22 WHITE/ORANGE36 WHITE/RED/GREEN
9 VIOLET 23 WHITE/SLATE37 WHITE/RED/BLUE
10 SLATE 24 WHITE/VIOLET38 WHITE/RED/BROWN
11 PINK 25 WHITE/BLACK/RED39 WHITE/RED/VIOLET
12 TAN 26 WHITE/BLACK/GREEN40 WHITE/GREEN/BLACK
13 RED/GREEN 27 WHITE/BLACK/YELLOW 
14 RED/YELLOW 28 WHITE/BLACK/BLUE 
2) Cable Assembly 40 Components Cabled 
a) Twists: 2.0 Twists/foot (min) 
b) Orientation: Components to be arranged from INSIDE LAYER to OUTSIDE LAYER 
c) Core Wrap Nonwoven Polyester Tape, 25% Overlap, Min. 
3) Shield: Alum/Mylar Tape, 25% Overlap, Min. 
a) Foil Direction Foil Facing In 
b) Drain Wire 20 (7/28) AWG Tinned Copper 
4) Jacket 0.065" Wall, Nom.,TPE0.650 (0.677 Max.)
a) Color(s) Slate, Black, Yellow, Orange, Blue, Green, Red, Sand Beige, White
b) Ripcord 1 End 810 Denier Nylon 
c) Print ALPHA WIRE-* P/N 45470/40 40C 20 AWG
XTRAGUARD(R) 4 (UL) TYPE PLTC 105C SUN RES OR AWM
20237/21918 125C 300 V OR
CRU AWM I/II A/B 125C 300 V FT1
P-07-KA140023-MSHA CE ROHS
(SEQ FOOTAGE)
* = Factory Code
1) UL AWM/STYLE 20237 125°C / 300 VRMS
 PLTC 105°C
 AWM/STYLE 21918 125°C / 300 VRMS
 SUN RES 
2) CSA International C(RU) AWM I/II A/B FT1 125°C / 300 VRMS
 SUN RES (Black only) 
3) Other PENNSYLVANIA BUREAU OF MINE SAFETY APPROVED 
4) CE:EU Low Voltage Directive 2014/35/EC
1) CE: EU Directive 2011/65/EU(RoHS2), EU Directive 2015/863/EU (RoHS3):
 This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011 and the amending Directive 2015/863/EU of 4 June 2015 . No Exemptions are required for RoHS Compliance on this item. Consult Alpha Wire's web site for RoHS C of C.
2) REACH Regulation (EC 1907/2006):
 This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, please see Alpha's REACH SVHC Declaration.
3) California Proposition 65:Exempt from warning labels based on the Consent Judgment. Please see Alpha's CA Prop 65 Statement for more information.
Physical & Mechanical Properties
1) Temperature Range-50 to 125°C
2) Bend Radius 10X Cable Diameter
3) Pull Tension 358 Lbs, Maximum
4) Sunlight Resistance Yes
Electrical Properties(For Engineering purposes only)
1) Voltage Rating 300 VRMS
2) Capacitance 22.6 pF/ft @1 kHz, Nominal Conductor to Conductor
3) Ground Capacitance41 pF/ft @1 kHz, Nominal
4) Inductance0.19 µH/ft, Nominal
5) Conductor DCR10.4 Ω/1000ft @20°C, Nominal
6) OA Shield DCR6.4 Ω/1000ft @20°C, Nominal
PackagingFlange x Traverse x Barrel (inches)
a) 1000 FT 30 x 14 x 12 Continuous length
b) 500 FT 24 x 14 x 12 Continuous length
c) Bulk(Made-to-order) 
 [Spool dimensions may vary slightly]
Notes:
a) Print legend will contain CSA SUN RES on black cables only.

Xtra-Guard® 4 - Handles extreme hot and cold temperatures High TemperatureLow TemperatureUltraviolet LightEMI Noise

  • Extended-temperature cable with a temperature range from -50°C to +125°C
  • Features a high-performance TPE insulation and jacket offering three times the low-temperature flexibility of ordinary PVC
  • Outstanding ultraviolet light stability in all jacket colors
  • UL Rated TC 600 V and PLTC 300 V for cable tray applications (except 24 AWG)
  • Pennsylvania Bureau Deep Mining Safety approved for mine-wide monitoring systems
  • Provides exceptional protection against EMI interference when Supra-Shield is specified

Request a Sample Download Brochure Consult a Cable Expert

Need a more unique construction? Different color code? Different color Jacket?

Request a Custom Quote Resources
AlphaWire