Part # Construction Type  RG Type  Impedance  Shielding  AWG  Stranding  Core Diameter  Jacket Diameter  Applicable Specifications 
9830 COAX  59/U  75  BRAID  22  Solid  0.146  0.242  CA Prop 65, MIL - JAN-C-17A/RG-59/U, UL AWM 1354 
(Ctrl+Click if PDF doesn't appear)
 Diameters (In)
1) Component 1 1 X 1 COAX 
a) Conductor 22 (SOLID) AWG BCW 0.025
b) Insulation 0.0605" Wall, Nom. Polyethylene(PE) 0.146
(1) Color(s)  
Cond Color Cond Color Cond Color
1 NATURAL   
2) Shield BC BRAID Shield,85% Coverage, Min. 
3) Jacket 0.037" Wall, Nom.,Type I PVC0.242+/- 0.006
a) Color(s) BLACK
b) Print ALPHA WIRE-* P/N 9830
RG-59/U TYPE 450MHZ 1C22 SHIELDED 60C EXXXXX AWM
1354 OR (UL) CMX C(UL) CE ROHS
(SEQ FOOTAGE -2FT)
* = Factory Code
[Note: Product may have c(UL) or CSA markings depending upon plant of manufacture.]
1) UL AWM/STYLE 1354 60°C / 30 VRMS
 CMX 60°C
2) CSA International C(UL) TYPE CMX 60°C
3) Military JAN-C-17A / RG-59/U 
4) CE:EU Low Voltage Directive 2006/95/EC
1) CE: EU Directive 2011/65/EU(RoHS2):
 This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011. No Exemptions are required for RoHS Compliance on this item. Consult Alpha Wire's web site for RoHS C of C.
2) REACH Regulation (EC 1907/2006):
 This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, please see Alpha's REACH SVHC Declaration.
3) California Proposition 65:The outer surface materials used in the manufacture of this part meet the requirements of California Proposition 65.
Physical & Mechanical Properties
1) Temperature Range-20 to 60°C
2) Bend Radius 10X Cable Diameter
3) Pull Tension 9.6 Lbs, Maximum
Electrical Properties(For Engineering purposes only)
1) Voltage Rating 1700 VRMS
2) Characteristic Impedance 75 Ω +/- 3
3) Ground Capacitance 21.5 pf/ft @1 kHz, Nominal
4) Velocity of Propagation 66 %
5) Conductor DCR 41 Ω/1000ft @20°C, Nominal
6) OA Shield DCR 5 Ω/1000ft @20°C, Nominal
7) Voltage Withstanding 7 kV, Minimum
8) Corona Extinction 2.3 kV, Minimum
9) Attenuation, Max dB/100ft 2.4 @ 100 MHz
  4.9 @ 200 MHz
  7.1 @ 400 MHz
PackagingFlange x Traverse x Barrel (inches)
a) 1000 FT 12 x 12 x 3.5 Continuous length
b) 500 FT 12 x 4.5 x 3.5 Continuous length
c) 100 FT 6.5 x 4 x 2.5 Continuous length
 [Spool dimensions may vary slightly]

For a complete range of 50, 75, 93, and 100 ohm coaxial, twinaxial, and triaxial cables, we offer a wide range of insulations and jackets meeting the requirements of military specifications and regulatory agencies such as UL and CSA. For broadcastquality video transmission, our precision video cables use FEP dielectrics to achieve low capacitance, high velocities of propagation, and tight tolerances for maximum signal integrity.