Part # Type  Shielding  Voltage  AWG  # of Elements  Jacket Diameter  Applicable Specifications 
XM0804R Conductor  UNSHIELDED  600/1000  0.737  CA Prop 65, CE, CSA AWM I/II A/B, CSA FT4, ROHS - RoHS Compliance, UL EXPOSED RUN, UL MTW, UL OIL RES I, UL SUN RES, UL TC, UL WTTC 
(Ctrl+Click if PDF doesn't appear)
 Diameters (In)
1) Component 1 4 X 1 COND 
a) Conductor 8 (168(7x24)/30) AWG BC 0.167
b) Insulation 0.032" Wall, Nom. PVC/ 0.006" Wall NYLON 0.243
(1) Print ALPHANUMERIC NUMBERS - 1-ONE ALTERNATING AND
INVERTED
(2) Color Code Alpha Wire Color Code RX
Cond Color Cond Color Cond Color
1 GREEN/YELLOW 3 RED#2 
2 RED#1 4 RED#3 
2) Cable Assembly 4 Components Cabled 
a) Twists: 2.1 Twists/foot (min) 
b) Core Wrap REMAY Tape, 25% Overlap, Min. 
3) Jacket 0.065" Wall, Nom.,PVC0.737+/- 0.028
a) Color(s) BLACK
b) Print ALPHA WIRE-* P/N XM0804R 4C 8 AWG (8.51mm2)
SERIES XM (UL) WTTC 90C DRY 75C WET 1000V OR
(UL) TC-ER 90C DRY 75C WET 600V SUN RES
DIR BUR OIL RES I OR MTW 8 AWG
--- LLXXXXXX CSA AWM I/II A/B 90C 600V FT4
CE ROHS (DATE CODE) (SEQ FOOTAGE)
* = Factory Code
[Note: Product may have c(UL) or CSA markings depending upon plant of manufacture.]
1) UL   
a) Component 1 Unlisted Conductor 90°C Dry / 75°C Wet / 600 VRMS
b) Overall MTW 90°C Dry / 60°C Wet / 600 VRMS
 TC 90°C Dry / 75°C Wet / 600 VRMS
 EXPOSED RUN 
 SUN RES 
 OIL RES I 
 WTTC 90°C Dry / 75°C Wet / 1000 VRMS
2) CSA International AWM I/II A/B 90°C / 600 VRMS
 FT4 
3) CE:EU Low Voltage Directive 2006/95/EC
1) CE: EU Directive 2011/65/EU(RoHS2):
 This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011. No Exemptions are required for RoHS Compliance on this item. Consult Alpha Wire's web site for RoHS C of C.
2) REACH Regulation (EC 1907/2006):
 This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, please see Alpha's REACH SVHC Declaration.
3) California Proposition 65:The outer surface materials used in the manufacture of this part meet the requirements of California Proposition 65.
Physical & Mechanical Properties
1) Temperature Range-30 to 90°C(static), -5 to 90°C (dynamic)
2) Bend Radius 8X Cable Diameter(static), 10X Cable Diameter(dynamic)
3) Pull Tension 528 Lbs, Maximum
4) Sunlight Resistance Yes
Electrical Properties(For Engineering purposes only)
1) Voltage Rating 600/1000 VRMS
2) Capacitance 35 pf/ft @1 kHz, Nominal Conductor to Conductor
3) Inductance0.16 µH/ft, Nominal
4) Conductor DCR0.66 Ω/1000ft @20°C, Nominal
PackagingFlange x Traverse x Barrel (inches)
a) Bulk(Made-to-order) 

A Tougher Cable for Continuous Flex Control Applications

Series XM Flex Control Cable is the ideal choice for medium-to-high-flex applications.  Featuring a premium-grade PVC jacket, Series XM offers a durable, oil-resistant construction that prevents contamination from hazardous fluids and protects against abrasion.  Plus, its optimum flexibility and performance allows it to support a variety of industrial applications, including:

  • High-speed pick-and-place robotic systems
  • Automated material handling equipment
  • Conveyors and transfer shuttles
  • Flex track installations

Series XM Product Breakdown:

  • Meets NFPA Standard 79 for industrial machinery
  • Stranded conductors for better flexibility
  • Specially formulated PVC jacket and insulation for continuous flex applications and resistance to moisture, oils, coolants, and UV radiation
  • Up to 65 conductors
  • 8 to 18 AWG wire range
  • Shielded or unshielded
  • Black, blue, or red insulation for AC and DC circuits
  • Rated for up to 12 million flex life cycles

Request a Sample Download Brochure Consult a Cable Expert

Need a more unique construction? Different color code? Different color Jacket?

Request a Custom Quote Resources
AlphaWire