Part # Type  Shielding  Voltage  AWG  # of Elements  Jacket Material  Insulation Material  Jacket Diameter  Applicable Specifications 
58812 Composite  FOIL  150  24+24  13  PVDF  FEP  0.294  CA Prop 65, CSA CMP, CSA FT6, UL CL2P 
(Ctrl+Click if PDF doesn't appear)
 Diameters (In)
1) Component 1 12 X 1 PAIR 
a) Conductor 24 (7/32) AWG TC 0.024
b) Insulation 0.007" Wall, Nom. FEP 0.038
(1) Color Code Alpha Wire Color Code N
Pair Color Pair Color Pair Color
1 BLACK-YELLOW 5 BLACK/WHITE-WHITE/BLACK9 YELLOW/WHITE-WHITE/YELLOW
2 RED-VIOLET 6 BROWN/WHITE-WHITE/BROWN10 GREEN/WHITE-WHITE/GREEN
3 BLUE-BROWN 7 RED/WHITE-WHITE/RED11 BLUE/WHITE-WHITE/BLUE
4 ORANGE-GREEN 8 ORANGE/WHITE-WHITE/ORANGE12 VIOLET/WHITE-WHITE/VIOLET
c) Pair 2/Cond Cabled Together 
(1) Twists: 12.0 Twists/foot (min) 
2) Component 2 1 X 1 COND 
a) Conductor 24 (7/32) AWG TC 
b) Insulation 0.007" Wall, Nom. FEP 
(1) Color(s)  
Cond Color Cond Color Cond Color
1 GREEN/YELLOW   
3) Cable Assembly 13 Components Cabled 
a) Twists: 3.0 Twists/foot (min) 
b) Core Wrap Clear Mylar Tape, 25% Overlap, Min. 
4) Shield: Alum/Mylar Tape, 25% Overlap, Min. 
a) Foil Direction Foil Facing In 
b) Drain Wire 24 (7/32) AWG TC 
5) Jacket 0.011" Wall, Nom.,PVDF0.294 (0.317 Max.)
a) Color(s) SLATE
b) Print ALPHA WIRE-* P/N 58812 12PR / 1C 24 AWG
SHIELDED 125C (UL) TYPE CMP OR C(UL) TYPE CMP FT6
CE ROHS
* = Factory Code
[Note: Product may have c(UL) or CSA markings depending upon plant of manufacture.]
1) UL CMP 125°C
2) CSA International FT6 
 C(UL) TYPE CMP 125°C
3) CE:EU Low Voltage Directive 2006/95/EC
1) CE: EU Directive 2011/65/EU(RoHS2), EU Directive 2015/863/EU (RoHS3):
 This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011 and the amending Directive 2015/863/EU of 4 June 2015 . No Exemptions are required for RoHS Compliance on this item.
2) REACH Regulation (EC 1907/2006):
 This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item.
3) California Proposition 65:Exempt from warning labels based on the Consent Judgment. Please see Alpha's CA Prop 65 Statement for more information.
Physical & Mechanical Properties
1) Temperature Range -25 to 125°C
2) Bend Radius 10X Cable Diameter
3) Pull Tension 91 Lbs, Maximum
Electrical Properties (For Engineering purposes only)
1) Voltage Rating 150 VRMS
2) Component 1
a) Characteristic Impedance 85 Ω +/- 10
b) Inductance 0.17 µH/ft, Nominal
c) Mutual Capacitance 18 pF/ft @1 kHz, Nominal
d) Ground Capacitance 32 pF/ft @1 kHz, Nominal
e) Conductor DCR 26 Ω/1000ft @20°C, Nominal
3) Component 2
a) Conductor DCR 26 Ω/1000ft @20°C, Nominal
b) OA Shield DCR 13.4 Ω/1000ft @20°C, Nominal
PackagingFlange x Traverse x Barrel (inches)
a) 1000 FT 16 x 11 x 8 Max. 3 separate pieces; Min length/piece 250 FT.
b) 500 FT 12 x 10 x 5 Continuous length
 [Spool dimensions may vary slightly]

Alpha Essentials Plenum Cable:

We offer a full range of cables for control, computer interconnections, security, alarms, and building energy management systems in a variety of plenum-rated insulation and jacket materials.


Request a Sample Download Brochure Consult a Cable Expert

Need a more unique construction? Different color code? Different color Jacket?

Request a Custom Quote Resources
AlphaWire