Part # Type  Shielding  Voltage  AWG  # of Elements  Jacket Material  Jacket Diameter  Applicable Specifications 
M2462 Conductor  FOIL_BRAID  300  24  PVC  0.3  CA Prop 65, CSA CM, CSA FT4, UL AWM 2919, UL CM, UL VW-1 
(Ctrl+Click if PDF doesn't appear)
 Diameters (In)
1) Component 1 9 X 1 COND 
a) Conductor 24 (7/32) AWG TC 0.024
b) Insulation 0.016" Wall, Nom. Polypropylene, Foam 0.056
(1) Color Code Alpha Wire Color Code O
Cond Color Cond Color Cond Color
1 BLACK 4 GREEN7 ORANGE
2 WHITE 5 BROWN8 YELLOW
3 RED 6 BLUE9 VIOLET
2) Cable Assembly 9 Components Cabled 
a) Twists: 4.0 Twists/foot (min) 
3) Shield: Alum/Mylar Tape, 25% Overlap, Min. 
a) Foil Direction Foil Facing Out 
b) Drain Wire 24 (7/32) AWG TC 
c) Braid TC,65% Coverage, Min. 
4) Jacket 0.035" Wall, Nom.,PVC0.300 (0.314 Max.)
a) Color(s) SLATE
b) Ripcord 1 End 810 Denier Nylon 
c) Print ALPHA WIRE-* P/N M2462 9C 24 AWG
EXXXXXX 75C CM (UL) C(UL) OR AWM 2919
CE ROHS
* = Factory Code
[Note: Product may have c(UL) or CSA markings depending upon plant of manufacture.]
1) UL AWM/STYLE 2919 80°C / 30 VRMS
 CM 75°C
 VW-1 
2) CSA International FT4 
 C(UL) TYPE CM 75°C
3) CE:EU Low Voltage Directive 2006/95/EC
1) CE: EU Directive 2011/65/EU(RoHS2), EU Directive 2015/863/EU (RoHS3):
 This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011 and the amending Directive 2015/863/EU of 4 June 2015 . No Exemptions are required for RoHS Compliance on this item.
2) REACH Regulation (EC 1907/2006):
 This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item.
3) California Proposition 65:Exempt from warning labels based on the Consent Judgment. Please see Alpha's CA Prop 65 Statement for more information.
Physical & Mechanical Properties
1) Temperature Range-20 to 80°C
2) Bend Radius 10X Cable Diameter
3) Pull Tension 39 Lbs, Maximum
Electrical Properties(For Engineering purposes only)
1) Voltage Rating 300 VRMS
2) Capacitance 11.9 pf/ft @1 kHz, Nominal Conductor to Conductor
3) Ground Capacitance21.4 pf/ft @1 kHz, Nominal
4) Inductance0.22 µH/ft, Nominal
5) Conductor DCR26 Ω/1000ft @20°C, Nominal
6) OA Shield DCR4.1 Ω/1000ft @20°C, Nominal
PackagingFlange x Traverse x Barrel (inches)
a) 1000 FT 16 x 11 x 8 Continuous length
b) 500 FT 12 x 10 x 5 Continuous length
c) 100 FT 12 x 4.5 x 3.5 Continuous length
d) Bulk(Made-to-order) 
 [Spool dimensions may vary slightly]

Communication and Control Cable:

Get Control Of Your Communication and Control Applications

Our line-up of standard communication and control cables gives you maximum choice and fewer tradeoffs. By offering you a comprehensive collection of insulation/jacketing materials, shielding options, and conductor counts, you can easily select the cable that meets your most demanding needs. We have cables that go beyond the ordinary to satisfy rigorous requirements of EMI performance, transmission distances, flexibility, and temperature extremes.

Communication and Control Typical applications:

  • Audio systems: speakers, microphones, intercoms

  • Broadcast and studio

  • Data transmission: RS-232, 422, 485

  • CAD/CAM

  • Computer peripherals

  • Business machines

  • Security systems: alarms, cameras, sensors

  • Control systems

  • Instrumentation systems

  • Point-of-sale systems

  • Banking systems

Low capacitance cables for improved transmission distances and signal integrity.

Request a Sample Download Brochure Consult a Cable Expert

Need a more unique construction? Different color code? Different color Jacket?

Request a Custom Quote Resources
AlphaWire