Part # Type  Shielding  Voltage  AWG  # of Elements  Jacket Material  Jacket Diameter  Applicable Specifications 
6314 Pair  UNSHIELDED  350  20  PE  0.291  CA Prop 65 
(Ctrl+Click if PDF doesn't appear)
 Diameters (In)
1) Component 1 3 X 1 PAIR 
a) Conductor 20 (10/30) AWG TC 0.037
b) Insulation 0.008" Wall, Nom. Polypropylene(PP) 0.053
(1) Color Code Alpha Wire Color Code A
Pair Color Pair Color Pair Color
1 BLACK-RED 2 BLACK-WHITE3 BLACK-GREEN
c) Pair 2/Cond Cabled Together 
(1) Twists: 8.0 Twists/foot (min) 
Individually Applied:
d) Shield: Foil Free Alum/Mylar Tape, 25% Overlap, Min. 
(1) Foil Direction Foil Facing In 
(2) Drain Wire 22 (7/30) AWG TC 
2) Cable Assembly 3 Components Cabled 
a) Twists: 4.0 Twists/foot (min) 
3) Jacket 0.040" Wall, Nom.,Polyethylene (PE)0.291 (0.305 Max.)
a) Color(s) BLACK
b) Print ALPHA WIRE-* P/N 6314
CE ROHS
* = Factory Code
1) CE:EU Low Voltage Directive 2006/95/EC
1) CE: EU Directive 2011/65/EU(RoHS2), EU Directive 2015/863/EU (RoHS3):
 This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011 and the amending Directive 2015/863/EU of 4 June 2015 . No Exemptions are required for RoHS Compliance on this item. Consult Alpha Wire's web site for RoHS C of C.
2) REACH Regulation (EC 1907/2006):
 This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, please see Alpha's REACH SVHC Declaration.
3) California Proposition 65:Exempt from warning labels based on the Consent Judgment. Please see Alpha's CA Prop 65 Statement for more information.
Physical & Mechanical Properties
1) Temperature Range-20 to 80°C
2) Bend Radius 10X Cable Diameter
3) Pull Tension 64 Lbs, Maximum
Electrical Properties(For Engineering purposes only)
1) Voltage Rating 350 VRMS
2) Mutual Capacitance31 pf/ft @1 kHz, Nominal
3) Ground Capacitance56 pf/ft @1 kHz, Nominal
4) Characteristic Impedance48 Ω
5) Inductance0.16 µH/ft, Nominal
6) Conductor DCR11.6 Ω/1000ft @20°C, Nominal
7) Component Shield DCR13.8 Ω/1000ft @20°C, Nominal
PackagingFlange x Traverse x Barrel (inches)
a) 1000 FT 16 x 11 x 8 Continuous length
b) 500 FT 12 x 10 x 5 Continuous length
 [Spool dimensions may vary slightly]

Communication and Control Cable:

Get Control Of Your Communication and Control Applications

Our line-up of standard communication and control cables gives you maximum choice and fewer tradeoffs. By offering you a comprehensive collection of insulation/jacketing materials, shielding options, and conductor counts, you can easily select the cable that meets your most demanding needs. We have cables that go beyond the ordinary to satisfy rigorous requirements of EMI performance, transmission distances, flexibility, and temperature extremes.

Communication and Control Typical applications:

  • Audio systems: speakers, microphones, intercoms

  • Broadcast and studio

  • Data transmission: RS-232, 422, 485

  • CAD/CAM

  • Computer peripherals

  • Business machines

  • Security systems: alarms, cameras, sensors

  • Control systems

  • Instrumentation systems

  • Point-of-sale systems

  • Banking systems

Low capacitance cables for improved transmission distances and signal integrity.

Request a Sample Download Brochure Consult a Cable Expert

Need a more unique construction? Different color code? Different color Jacket?

Request a Custom Quote Resources
AlphaWire